Type R thermocouple

Pt-13 % Rh / Pt · -50 … 1768.1 °C · IEC 60584-1

At a glance

Conductors (+ / −)
Pt-13 % Rh / Pt
Range of the reference function
-50 … 1768.1 °C
Sensitivity at 1000 °C
13.23 µV/°C
Class 1 tolerance
±1 °C up to 1100 °C, then ±(1 + 0.003 × (t − 1100)) °C, 0 to 1600 °C
Class 2 tolerance
±1.5 °C up to 600 °C, then ±0.0025 × t, 0 to 1600 °C

Wire colours

PositiveNegativeSheath / Jacket
IEC 60584-3 (international)orangewhiteorange
ASTM E230 / ANSI (USA), extension wireblackredgreen

Colours identify the type, not the quality of the cable. Older national codes (e.g. BS 1843, DIN 43714, JIS) used other colours; check before reusing existing cable.

EMF at common temperatures (0 °C reference)

Temperature (°C)EMF (mV)Sensitivity (µV/°C)
00.0005.29
2001.4698.84
4003.40810.37
6005.58311.36
8007.95012.31
100010.50613.23
120013.22813.92
140016.04014.13
160018.84913.88

Full type R EMF tableThermocouple calculator

Typical use and limits

Platinum-13 % rhodium against platinum, for high temperatures up to about 1600 °C in furnaces, glass production and reference work. The output is low, about 10 to 14 µV/°C over most of the range, so the measuring electronics and the cold junction must be good. Protect the wire from metal vapours and reducing atmospheres with ceramic tubes.