SensorCatalog

Type E thermocouple

Ni-Cr / Cu-Ni · -270 … 1000 °C · IEC 60584-1

At a glance

Conductors (+ / −)
Ni-Cr / Cu-Ni
Range of the reference function
-270 … 1000 °C
Sensitivity at 300 °C
77.91 µV/°C
Class 1 tolerance
±1.5 °C or ±0.004 × |t|, whichever is larger, -40 to 800 °C
Class 2 tolerance
±2.5 °C or ±0.0075 × |t|, whichever is larger, -40 to 900 °C
Class 3 tolerance
±2.5 °C or ±0.015 × |t|, whichever is larger, -200 to 40 °C
Extension and compensating cable
EXIEC 60584-3: X = extension cable of the same alloys, C = compensating cable of other alloys, matched over a limited temperature range

Wire colours

PositiveNegativeSheath / Jacket
IEC 60584-3 (international)violetwhiteviolet
ASTM E230 / ANSI (USA), extension wirepurpleredpurple

Colours identify the type, not the quality of the cable. Older national codes (e.g. BS 1843, DIN 43714, JIS) used other colours; check before reusing existing cable.

EMF and tolerance at common temperatures (0 °C reference)

Temperature (°C)EMF (mV)Sensitivity (µV/°C)Class 1 (±°C)Class 2 (±°C)Class 3 (±°C)
-200-8.82525.13——±3.00
-100-5.23745.17——±2.50
00.00058.67±1.50±2.50±2.50
1006.31967.52±1.50±2.50—
20013.42174.03±1.50±2.50—
40028.94680.06±1.60±3.00—
60045.09380.66±2.40±4.50—
80061.01778.43±3.20±6.00—

—: the class is not defined at this temperature. Tolerance of type E at every 100 °C

Full type E EMF tableThermocouple calculator

Typical use and limits

The highest output per degree of the standard types, roughly 60 to 80 µV/°C, so it resolves small temperature differences well. Both legs are non-magnetic. Suited to oxidising and inert atmospheres and to sub-zero work.