Ex marking decoder

What an ATEX, IECEx or NEC hazardous-area marking means, and whether the equipment suits your zone, gas group and ignition temperature.

Marking

Your site

Result

GbZone 1 · 2

Suitable for the site as entered.

Equipment protection level
Gbzones 1, 2
Maximum surface temperature
135 °CT4
Suitable for groups
IIA, IIB, IICmarked IIC
Ambient range
-20 … +40 °Cstandard range, no Ta marked (IEC 60079-0)
Zone 1
suitablemarked EPL Gb
Group IIA
suitablemarked IIC

Breakdown

PartMeaning
IIEquipment group II: places other than mines, with gas or dust
2GCategory 2G: high protection, gas, zones 1 and 2
ExExplosion-protected equipment to the IEC 60079 series
dbFlameproof enclosure (IEC 60079-1), level of protection "b"
IICGas group IIC, e.g. hydrogen and acetylene; also suitable for IIB and IIA
T4Temperature class T4: maximum surface temperature 135 °C
GbEPL Gb: high protection; zones 1, 2
Formulas and standards

Selection follows IEC 60079-14. The equipment protection level must cover the zone (Ga: zones 0–2, Gb: 1–2, Gc: 2; Da: 20–22, Db: 21–22, Dc: 22). The equipment group must cover the substance (IIC covers IIB and IIA, IIIC covers IIIB and IIIA). For gas the maximum surface temperature must be below the ignition temperature; for dust it must not exceed 2/3 of the cloud ignition temperature, nor the 5 mm layer ignition temperature minus 75 K. Without a marked ambient range the equipment is rated for −20 to +40 °C. The certificate and its specific conditions of use (suffix X) always take precedence.

Need an ATEX or IECEx certified transmitter or sensor?

Get pricing from SensorSpan

Reading an Ex marking

Equipment for hazardous areas carries a marking that says how it is protected and where it may be used. A typical ATEX and IECEx marking for a pressure transmitter reads:

II 2G Ex db IIC T4 Gb

  • II: equipment group II, for places other than mines (ATEX)
  • 2G: ATEX category 2 for gas, high protection, for zones 1 and 2
  • Ex: explosion-protected equipment to the IEC 60079 series
  • db: flameproof enclosure (IEC 60079-1) with level of protection “b”
  • IIC: gas group IIC, which also covers IIB and IIA
  • T4: maximum surface temperature 135 °C
  • Gb: equipment protection level Gb, for zones 1 and 2

The decoder splits a marking into these parts, explains each one and works out the permitted zones, the gas or dust groups covered and the maximum surface temperature.

Zones and equipment protection levels

Hazardous areas are classified by how often an explosive atmosphere is present: zone 0, 1 or 2 for gas and zone 20, 21 or 22 for dust, from continuous to rare. IEC 60079-14 assigns the equipment protection level (EPL) each zone needs:

  • Zone 0: Ga · zone 1: Ga or Gb · zone 2: Ga, Gb or Gc
  • Zone 20: Da · zone 21: Da or Db · zone 22: Da, Db or Dc

The type of protection determines the level: intrinsic safety “ia” gives Ga, “ib” Gb, “ic” Gc; a flameproof enclosure “db” gives Gb.

Gas groups and temperature classes

Gases are grouped by how easily a flame passes through a gap and how little energy ignites them: IIA (e.g. propane), IIB (e.g. ethylene) and IIC (hydrogen, acetylene). Equipment for IIC may be used for IIB and IIA, not the other way round. Dusts are grouped as IIIA (combustible flyings), IIIB (non-conductive dust) and IIIC (conductive dust).

The temperature class limits the hottest surface: T1 450 °C, T2 300 °C, T3 200 °C, T4 135 °C, T5 100 °C, T6 85 °C. Dust equipment states the temperature directly, e.g. T85 °C.

Checking a site

Enter the zone, the substance group and its ignition temperature to check the equipment against IEC 60079-14:

  • The EPL must be permitted in the zone
  • The equipment group must cover the substance group
  • For gas, the maximum surface temperature must be below the ignition temperature
  • For dust, it must not exceed 2/3 of the cloud ignition temperature, nor the ignition temperature of a 5 mm layer minus 75 K

Without a marked ambient range (Ta), the equipment is rated for −20 to +40 °C.

North American markings

US and Canadian equipment may be marked to the Division system, e.g. “Class I, Division 1, Groups A, B, C, D, T4”, or to the zone system with an “AEx” prefix. The decoder explains classes (I gas, II dust, III fibres), divisions and the groups A to G.

Common mistakes

Reading the category or EPL in isolation. Both must match the zone; a Gc device is not permitted in zone 1, however high its gas group.

Ignoring the suffix X. A certificate number ending in X has specific conditions of use, such as impact protection or a limited ambient range. They are part of the approval.

Matching only the gas group. A IIC device with T6 can still be unsuitable if the ambient temperature exceeds its marked range.

Frequently asked questions

Does the decoder replace the certificate?

No. It explains the marking. The certificate, the manufacturer’s instructions and the specific conditions of use are binding.

What about intrinsically safe loops?

An “ia” or “ib” transmitter must be connected through a suitable barrier or isolator, and the loop parameters (Ui, Ii, Pi, Ci, Li) must match. The loop power calculator checks the voltage budget, including the barrier’s resistance.

Can it read several markings at once?

Enter one marking at a time, e.g. the gas marking and the dust marking of a dual-rated device separately.