VPD calculator

Vapour-pressure deficit from air temperature and relative humidity, after FAO-56.

At 25 °C the saturation vapour pressure is 3.168 kPa, so at 60 % RH the vapour-pressure deficit is 1.267 kPa (FAO-56); at 30 °C and 50 % RH it is 2.121 kPa.

Air

Result

1.267kPa

es 3.17 kPa at 60 % RH

Saturation pressure
3.168 kPaes at this temperature
VPD
1.267 kPaes − e
Vapour pressure
1.901 kPaactual e = es · RH/100
Valid range
-40 … 60 °C

Schematic

VPD1.267 kPa02.5 kPaSaturation pressure3.168 kPaRelative humidity60 %
Drawn from the inputs above; not to scale.
Formulas and standards
es = 0.6108 · exp(17.27·T / (T + 237.3))   VPD = es · (1 − RH/100)

The saturation vapour pressure es is the maximum water vapour pressure the air can hold at that temperature; the vapour-pressure deficit is the difference between that maximum and the actual vapour pressure, VPD = es · (1 − RH/100). A large VPD means dry air with a strong drying pull, a VPD near zero means the air is close to saturation and condensation is likely on any colder surface. The same air has a VPD that rises steeply with temperature even when the relative humidity does not change.

The Tetens form and the constants are the ones in FAO Irrigation and Drainage Paper 56 (0.6108 kPa, 17.27, 237.3). The site’s dew-point and absolute-humidity tools use the WMO/Sonntag curve; above freezing the two agree within 0.5 %. VPD targets for crops, buildings or drying processes are process-specific and are not set on this page — it gives the physical quantity only.

Looking for humidity and temperature sensors for a controlled environment?

Contact us

What VPD means

The saturation vapour pressure is the most water vapour the air can hold at a given temperature. The vapour-pressure deficit (VPD) is the gap between that maximum and the water vapour actually present:

  • VPD = es · (1 − RH/100) kPa

A large VPD means dry air with a strong pull on water; a small VPD means the air is close to saturation. It is the quantity used when the drying power of air matters — greenhouses, drying rooms, paint booths, clean rooms and HVAC — while relative humidity is the quantity used when condensation on a surface is the question.

The FAO-56 formula

FAO Irrigation and Drainage Paper 56 gives the saturation pressure with the Tetens form:

  • es = 0.6108 · exp(17.27 · T / (T + 237.3)) kPa

with T in °C, valid over the range this calculator uses (−40 to 60 °C). The vapour pressure is then e = es · RH/100 and the deficit is es − e. The constants are the ones printed in the paper, so the numbers match the reference tables used in irrigation and agronomy.

Worked example

At 25 °C:

  • es = 0.6108 · exp(17.27 · 25 / 262.3) = 3.168 kPa
  • at 60 % RH, e = 1.901 kPa and VPD = 3.168 − 1.901 = 1.267 kPa
  • at 40 % RH, VPD = 1.901 kPa; at 90 % RH it is 0.317 kPa

At 30 °C and 50 % RH the same arithmetic gives es = 4.243 kPa and VPD = 2.121 kPa. Raising the temperature at constant relative humidity increases the VPD much faster than the relative humidity suggests, because es grows roughly 6–7 % per kelvin near room temperature.

VPD and relative humidity

Relative humidity says how full the air is relative to its own temperature; VPD says how much vapour pressure is missing. Two rooms at 25 °C/60 % and 30 °C/70 % have different VPDs even though both feel humid: the warmer room can hold more water, so its deficit is larger. That is why VPD is used to compare drying conditions across temperatures and why a control loop on VPD holds a different relative humidity at each setpoint.

Where it is used

  • Greenhouses and growth rooms: VPD links transpiration to the air’s drying power; the setpoints are crop-specific.
  • Drying and coating: the evaporation rate follows the vapour-pressure deficit, not the relative humidity alone.
  • HVAC and clean rooms: a low VPD is the warning that condensation will form on a cold surface; the dew-point calculator gives that temperature directly.
  • Compressed air and process gas: VPD is rarely quoted, but the same saturation curve underlies the absolute humidity calculator and the pressure dew point.

Common mistakes

Using VPD as a relative-humidity target. VPD is a pressure difference in kPa; a control system that needs %RH must convert it with the current temperature.

Assuming VPD is constant when air is heated. Heating at constant absolute humidity raises VPD sharply; the dew point and absolute humidity do not change.

Mixing formulas. FAO-56 uses 17.27/237.3; the WMO uses 17.62/243.12. Above freezing they agree within about 0.5 %, so a small difference between two tools is the formula, not a bug — check which one a datasheet used.

Ignoring the leaf or surface temperature. For a greenhouse, the relevant VPD often uses leaf temperature, not air temperature; the calculator gives the air value.

Frequently asked questions

Is VPD the same as relative humidity?

No. Relative humidity is a percentage of the saturation pressure at the same temperature; VPD is the difference between the saturation pressure and the actual vapour pressure, in kPa.

What is a good VPD?

It depends on the crop or process. The calculator gives the physical value; setpoints come from the crop or process specification, not from a universal number.

Does VPD change when air is heated?

Yes. At constant absolute humidity, heating lowers relative humidity and raises VPD steeply; the dew point stays the same.