SensorCatalog

MEMS inclinometer & tilt angle calculator

Static gravity projection, single-axis sensitivity drop past 45° and dual-axis atan2 offset error.

At 30° tilt, a MEMS accelerometer sees a_x = 0.5000 g and sensitivity drops to 15.11 mg/°; a 10 mg offset causes ±0.57° error with dual-axis atan2.

Orientation and sensor

Result

+0.5000g

θ = 30.0° → a_x = 0.5000 g · sensitivity 15.1 mg/°

Z-axis gravity (a_z)
0.8660 gcos(θ)
Single-axis sensitivity
15.11 mg/°17.45 mg/° at 0°
1-axis arcsin error
±0.66 °blows up near ±90°
2-axis atan2 error
±0.57 °constant 0.057°/mg

Schematic

MEMS IMU1.00 g30.0°a_x = +0.5000 ga_z = 0.8660 g2-axis atan2 err: ±0.57°
Formulas and standards
a_x = sin(θ) g   d(a_x)/dθ = cos(θ) · (π/180)   θ = atan2(a_x, a_z)

A MEMS accelerometer senses a_x = sin(θ) g and a_z = cos(θ) g. Single-axis sensitivity falls as cos(θ), whereas dual-axis θ = atan2(a_x, a_z) keeps constant resolution across 360°.

Dynamic machine vibration adds directly to static gravity g; apply low-pass filtering or fuse with a MEMS gyroscope for moving vehicles.

MEMS accelerometer gravity projection and tilt error

A static MEMS inclinometer projects Earth’s 1 g gravity vector onto orthogonal axes: a_x = sin(θ) g and a_z = cos(θ) g.

  • Single-axis sensitivity: d(a_x)/dθ = cos(θ) · 17.45 mg/°
  • Dual-axis tilt: θ = atan2(a_x, a_z) keeps constant 0.0573°/mg offset sensitivity across 360°

Worked example

At θ = 30°, a_x = 0.5000 g and a_z = 0.8660 g. Single-axis sensitivity drops from 17.45 to 15.11 mg/°, so a 10 mg offset causes ±0.66° error in 1-axis arcsin vs ±0.57° with 2-axis atan2.

Frequently asked questions

Why should I avoid single-axis arcsin tilt sensing past 45°?

Because d(sin θ)/dθ = cos θ approaches zero near ±90°: at 80°, sensitivity drops by 5.7× and any mg offset or noise causes huge angular errors. Always use dual-axis atan2(a_x, a_z).

How much angle error does a 10 mg accelerometer offset cause?

With dual-axis atan2, every 1 mg of zero-g offset introduces approximately 0.0573° of tilt error, so 10 mg causes ±0.57°.

Why do MEMS inclinometers jump on vibrating cranes or excavators?

Accelerometers cannot distinguish linear acceleration or vibration from gravity. Use a low-pass filter for slow machinery or a 6-axis IMU (accelerometer + gyroscope Kalman filter) for dynamic motion.

↑ ↓ choose · Enter open · Esc close