Current shunt resistor calculator

Voltage, dissipation and error of a current shunt, and the gain and resolution it needs ahead of an ADC.

Shunt

Given as

Rating

Current and input

Result

37.5mV

At 50 A. Dissipation at 100 A: 7.5 W.

Resistance
750 µΩ75 mV / 100 A
Voltage at highest current
75 mVat 100 A
Dissipation at highest current
7.5 Wchoose a power rating with margin
Dissipation
1.875 Wat 50 A
Tempco error
±0.2 %50 ppm/K × 40 K
Resistance error, worst case
±0.7 %tolerance + tempco; 350 mA at this current
Gain to full scale
—enter the full-scale input
Current per ADC code
—enter the full-scale input and ADC bits
Formulas and standards
R = Vrated / Irated   V = I × R   P = I² × R
ΔR / R = tolerance + TCR × ΔT

A shunt is a low-value resistor in the current path; the current is the voltage across it divided by its resistance. A rating such as 100 A / 75 mV means the shunt drops 75 mV at 100 A, so R = 0.75 mΩ. The power I² R heats the shunt, and its resistance changes with the temperature coefficient; the tempco error is TCR × temperature rise.

Measure the voltage at the shunt's sense terminals (four-terminal or Kelvin connection) so the contact resistance of the current terminals stays out of the measurement. Shunts are commonly operated well below their rated power to limit the temperature rise; follow the manufacturer's derating. The amplifier's offset voltage divided by R is a current error that matters most at low currents.

Need current sensors, shunts or Hall-effect transducers?

Get pricing from SensorSpan

How the current shunt calculator works

A shunt is a resistor of very low value placed in the current path; the current is the voltage across it divided by its resistance. Industrial shunts are rated by current and voltage drop, such as 100 A / 75 mV, while board-level current sense resistors are given in milliohms.

The calculator works from either. It gives the resistance, the voltage and dissipation at your current and at the highest current, the resistance error from tolerance and temperature coefficient, and the amplifier gain and current per ADC code when you enter the converter’s full-scale input.

Rating and resistance

A 100 A / 75 mV shunt drops 75 mV at 100 A, so R = 75 mV / 100 A = 0.75 mΩ. At 50 A it drops 37.5 mV and dissipates 1.9 W; at 100 A it dissipates 7.5 W. The dissipation heats the shunt, and its resistance changes with its temperature coefficient: 50 ppm/K over a 40 K rise is 0.2 %. Manufacturers state how far below the rated current a shunt should run continuously; follow their derating.

Choosing the voltage drop

A larger drop is easier to measure accurately but wastes power and heats the shunt. 50, 60, 75 and 100 mV are common for industrial shunts. On circuit boards, drops of 10 to 100 mV at full current are typical, chosen so the amplifier’s offset voltage stays small against the signal. Below about 10 mV at full current the offset and the thermoelectric voltages at the connections become a noticeable part of the reading.

Connections and amplifier

Measure at the shunt’s sense terminals, not at its current terminals. A four-terminal (Kelvin) connection keeps the resistance of the screw contacts and the cable out of the measurement. The amplifier’s offset divided by R is a current error that dominates at low currents: 100 µV on 0.75 mΩ is 0.13 A.

Enter the full-scale input of the amplifier or ADC to see the gain that brings the highest current to full scale, and the ADC bits to see the current per code. The ADC resolution calculator and the instrumentation amplifier gain calculator take the design further.

Frequently asked questions

High side or low side?

A low-side shunt, in the return to ground, is easy to measure but lifts the load’s ground. A high-side shunt keeps the ground intact but needs an amplifier that tolerates the common-mode voltage of the supply. Current sense amplifiers are built for the high side.

When is a Hall sensor better?

When the current is high, the circuit must be isolated, or the dissipation of a shunt is unacceptable. A closed-loop Hall transducer adds no heat in the conductor and gives isolation, at a higher cost and offset.

How does a current transformer compare?

A current transformer only measures alternating current and is limited by its burden; the current transformer burden calculator checks that. A shunt measures DC and AC alike.