SensorCatalog

6-Axis Force/Torque (F/T) Sensor Calculator

Transform robot TCP forces to the wrist F/T flange, include gripper weight, and verify Combined Load Factor (CLF) overload margin.

A 6-axis F/T sensor experiences both TCP forces and lever-arm bending moment My = Fx × dz plus gripper weight m·g. Verify Combined Load Factor CLF = (|Fx|+|Fz,tot|)/F_max + |My|/M_max ≤ 100% (≤ 80% for dynamic impacts).

Tool load & 6-axis F/T sensor rating

Result

109.8% CLF

Moment My = 9.00 N·m · Combined Load Factor = 110% · Safety factor 0.91×

Induced moment My
9.00 N·mFx × 150 mm
Total axial Fz
64.5 Nincl. gravity 2.5 kg
Resultant force |F|
88.1 N√(Fx² + Fz²)
Safety factor
0.91×OVERLOAD — exceeds combined F/T envelope

Schematic

RobotFlange6-AxisF/T150 mmLever Arm dz60 N65 NMy = 9.00 N·mCombined Load (CLF)110%Safe Limit ≤ 100%
Formulas and standards
M_y = F_x · d_z   F_z,tot = F_z + m·g   CLF = (|F_x| + |F_z,tot|)/F_max + |M_y|/M_max

A robot wrist 6-axis F/T sensor experiences both the applied TCP force and the bending moment My = Fx × dz created by the end-effector lever arm, plus static tool gravity m·g.

Most multi-axis load cells rate overload by the Combined Load Factor CLF = (|Fx| + |Fz,tot|)/F_max + |My|/M_max ≤ 100%. Always keep CLF below 80% for dynamic cobot impacts.

Wrench Transform and Lever-Arm Moments

A 6-axis force/torque (F/T) sensor mounted at a collaborative or humanoid robot wrist measures three orthogonal forces ($F_x, F_y, F_z$) and three moments ($M_x, M_y, M_z$). Whenever a gripper, polishing spindle, or suction end-effector extends by a lever arm $d_z$ from the sensor flange, any lateral contact force $F_x$ generates an amplified bending moment $M_y = F_x \cdot d_z$.

Even modest forces become dangerous at long tool offsets: a 60 N lateral push on a 150 mm gripper produces 9.0 N·m of bending moment, which often reaches the moment rating long before the axial force rating is exceeded.

Combined Load Factor (CLF) Overload Check

Multi-axis transducers share internal flexure beams across all six axes. Manufacturers therefore specify an interaction envelope using the Combined Load Factor:

$$\text{CLF} = \frac{|F_x| + |F_{z,\text{tot}}|}{F_{\max}} + \frac{|M_y|}{M_{\max}} \le 100%$$

For signal conditioning of internal strain-gauge bridges, inspect the Wheatstone Bridge & In-Amp Circuit or verify bridge sensitivity with the Strain Gauge Bridge Calculator.

Frequently Asked Questions

Why does a 6-axis F/T sensor overload even when Fx is below F_max?

Because all six channels share the same machined flexure element. A lateral force applied at a 150 mm tool offset creates a large bending moment My = Fx × dz that consumes most of the combined strain budget.

Should gripper and payload weight be included in Fz?

Yes. Static gravity m × 9.80665 m/s² shifts the zero baseline and directly consumes axial force capacity (and moment capacity whenever the wrist tilts horizontally). Always perform gravity compensation in firmware and size the hardware for full gravity plus impact load.

Keep static plus working CLF below 60% to 80% of rated capacity so unexpected collision spikes stay inside the elastic overload limit (typically 300% to 500% single-axis safe overload).

↑ ↓ choose · Enter open · Esc close