Wrench Transform and Lever-Arm Moments
A 6-axis force/torque (F/T) sensor mounted at a collaborative or humanoid robot wrist measures three orthogonal forces ($F_x, F_y, F_z$) and three moments ($M_x, M_y, M_z$). Whenever a gripper, polishing spindle, or suction end-effector extends by a lever arm $d_z$ from the sensor flange, any lateral contact force $F_x$ generates an amplified bending moment $M_y = F_x \cdot d_z$.
Even modest forces become dangerous at long tool offsets: a 60 N lateral push on a 150 mm gripper produces 9.0 N·m of bending moment, which often reaches the moment rating long before the axial force rating is exceeded.
Combined Load Factor (CLF) Overload Check
Multi-axis transducers share internal flexure beams across all six axes. Manufacturers therefore specify an interaction envelope using the Combined Load Factor:
$$\text{CLF} = \frac{|F_x| + |F_{z,\text{tot}}|}{F_{\max}} + \frac{|M_y|}{M_{\max}} \le 100%$$
For signal conditioning of internal strain-gauge bridges, inspect the Wheatstone Bridge & In-Amp Circuit or verify bridge sensitivity with the Strain Gauge Bridge Calculator.
Frequently Asked Questions
Why does a 6-axis F/T sensor overload even when Fx is below F_max?
Because all six channels share the same machined flexure element. A lateral force applied at a 150 mm tool offset creates a large bending moment My = Fx × dz that consumes most of the combined strain budget.
Should gripper and payload weight be included in Fz?
Yes. Static gravity m × 9.80665 m/s² shifts the zero baseline and directly consumes axial force capacity (and moment capacity whenever the wrist tilts horizontally). Always perform gravity compensation in firmware and size the hardware for full gravity plus impact load.
What safety margin is recommended for cobot assembly or humanoid contact?