How the defect frequencies are calculated
A rolling bearing produces four characteristic frequencies when a surface is damaged. They follow from the geometry and the shaft speed, not from the load or the sensor:
- BPFO, ball pass frequency outer race: (N/2)·fr·(1 − (Bd/Pd)·cos θ)
- BPFI, ball pass frequency inner race: (N/2)·fr·(1 + (Bd/Pd)·cos θ)
- BSF, ball spin frequency: (Pd/(2·Bd))·fr·(1 − ((Bd/Pd)·cos θ)²)
- FTF, fundamental train frequency (the cage): (fr/2)·(1 − (Bd/Pd)·cos θ)
N is the number of rolling elements, Bd the ball diameter, Pd the pitch diameter, θ the contact angle and fr the shaft frequency. The calculator returns both the order (the factor by which the shaft speed is multiplied) and the frequency in Hz, and accepts the shaft speed in rpm or Hz.
Worked example: 6205 bearing
The 6205-2RS JEM bearing used in many published test rigs has 9 balls, a ball diameter of 7.94 mm, a pitch diameter of 39.04 mm and a 0° contact angle. The ratios are:
- BPFO = 3.5848 × fr
- BPFI = 5.4152 × fr
- BSF = 2.357 × fr
- FTF = 0.3983 × fr
At 1500 rpm, fr is 25 Hz, so the BPFO sits at 89.6 Hz and the BPFI at 135.4 Hz. The sum of BPFO and BPFI is always N·fr, which is a quick sanity check on any bearing geometry.
Orders vs hertz
Orders are independent of speed, so they are the right way to compare a bearing across a variable-speed machine: the peak stays at the same order while the hertz scale moves with the shaft. Hertz is what the analyser displays, so the calculator gives both. If the speed is taken in rpm, divide by 60 before entering it in the formulas; the tool does this when the unit is set to rpm.
What real spectra look like
The formulas describe a perfect bearing. A real bearing slips by roughly 1–2 %, so a damaged outer race can show at 3.55× instead of 3.58×, and the peak may drift by a few percent with load and lubrication. The load zone modulates the amplitude, which produces sidebands at the shaft speed around BPFI and BSF, and harmonics of the defect frequency are common. Use the order as a hypothesis, then confirm it in the spectrum, the time waveform (impacts once per revolution for an outer-race defect) and the machine history.
Where each frequency comes from
- BPFO: the outer race is stationary, so the defect is struck by every ball once per cage revolution; the frequency is below N/2·fr.
- BPFI: the inner race rotates with the shaft, so the defect passes the load zone faster; the frequency is above N/2·fr.
- BSF: a defect on one ball strikes the races at the ball spin rate; it is usually weaker and often appears with FTF sidebands.
- FTF: the cage rotates slowly, at a fraction of shaft speed; a cage defect is rare but destructive.
Using the numbers in practice
Set the analyser’s frequency range to cover at least the BPFI, and prefer an accelerometer mounted close to the bearing housing; a magnet mount or a hand-held probe attenuates the high frequencies that carry the impacts. For a first pass, compare the measured peaks with the four orders, then confirm with an envelope (demodulation) measurement, which is more sensitive to bearing defects than the raw spectrum. The vibration converter converts between acceleration, velocity and displacement when the datasheet or the standard is stated in another quantity.
Record the shaft speed with the measurement. A peak at 3.58× is only meaningful if the speed is known; at variable speed, use order tracking or a tachometer.
Common mistakes
Using the bearing’s outside diameter as the pitch diameter. The pitch diameter is the circle through the ball centres, roughly halfway between bore and outside diameter; take it from the catalogue, not from the drawing outline.
Forgetting the contact angle. A deep-groove bearing is 0°, but an angular-contact or self-aligning bearing is not, and the error moves every order.
Expecting a peak exactly on the order. Slip, load and speed ripple move it by a few percent. Search a band around the calculated order, not a single line.
Diagnosing from one peak. A peak at BPFO can also come from a gear mesh harmonic or a resonance. Confirm with envelope analysis, the time waveform and a trend over time.
Frequently asked questions
What do BPFO and BPFI stand for?
Ball pass frequency, outer race and inner race: the rate at which rolling elements pass a defect on the outer or inner ring.
Why is BPFI higher than BPFO?
The inner race rotates with the shaft, so a point on it passes the rolling elements more often than a point on the stationary outer race. Their sum is always N times the shaft frequency.
Does the bearing calculator need the load or the lubricant?
No. The kinematic frequencies depend on geometry and speed only; load, lubrication and damage severity change the amplitude, not the order.
Can I use it for a gearbox bearing?
Yes, if you know the bearing geometry and the shaft speed at that bearing. In a gearbox the input speed must be converted through the gear ratio first.
Why does the measured peak differ from the calculated one?
Rolling-element slip typically shifts the frequency by 1–2 %, and speed measurement error adds to it. Search a band of a few percent around the order.
What frequency range should the analyser cover?
At least the BPFI, and preferably three to five harmonics of it. High-frequency envelope bands are usually set well above the defect orders.
Is a peak at the ball spin frequency a ball defect?
Usually, but BSF also appears from misalignment and from a damaged cage. Check for FTF sidebands and confirm with envelope analysis.