What the orifice equation gives
An orifice plate creates a pressure difference that grows with the square of the flow. The ISO 5167 equation turns a measured Δp into a volume flow:
- Q = C · ε · A₂ / √(1 − β⁴) · √(2·Δp / ρ)
A₂ is the bore area, β = d/D, C is the discharge coefficient and ε the expansibility factor. This page computes Q from those inputs; it does not calculate C or ε, because both depend on details the standard defines.
The inputs
- Pipe internal diameter D and orifice bore d, in millimetres; β = d/D must lie in the ISO range 0.1–0.75.
- Differential pressure Δp in kPa, measured across the taps.
- Density ρ at upstream conditions, in kg/m³.
- Discharge coefficient C, from ISO 5167-2 or the maker.
- Expansibility ε: exactly 1 for a liquid; for a gas, from the isentropic exponent and the pressure ratio.
Worked example
D = 100 mm, d = 60 mm, Δp = 25 kPa, water at 1000 kg/m³, C = 0.61, ε = 1:
- β = 0.6, A₂ = 0.0028274 m²
- 1/√(1 − 0.6⁴) = 1.07187
- Q = 0.61 × 1.07187 × 0.0028274 × √50 = 0.013072 m³/s = 47.06 m³/h
The pipe velocity follows from the same flow and the pipe area: 1.67 m/s.
Where C comes from
For an ISO 5167-2 orifice with flange taps, C is the Reader–Harris/Gallagher correlation: it depends on β, the pipe Reynolds number, the tap positions and the pipe roughness, and it lands between about 0.596 and 0.62 inside the standard’s limits. That is why a coefficient typed into a calculator is only as good as its source. Take C from the standard’s equation, from the maker’s sizing sheet, or from a calibrated baseline; do not assume 0.61 for every plate.
Limits of the standard
ISO 5167-2 applies to a defined geometry: a thin square-edged orifice, specified tap arrangements, a straight run upstream and downstream, β 0.1–0.75, D 50–1000 mm and a Reynolds number above about 5000. Outside those limits the uncertainty grows and the equation is no longer a standard measurement. A custody transfer or safety trip needs the standard’s full procedure, not a single equation. The flow rate converter and pressure converter help with the units around the measurement.
Common mistakes
Using gauge pressure instead of Δp. The equation needs the difference across the plate, in Pa.
Taking C = 0.61 blindly. The coefficient moves with β and Reynolds number; a few percent of error in C is a few percent of flow.
Forgetting the expansibility for gas. ε below 1 reduces the flow; using 1 for a gas over-reads.
Ignoring the installation. A valve or bend too close to the plate changes the profile and the coefficient.
Frequently asked questions
Is this a full ISO 5167 sizing?
No. It is the ISO 5167 flow equation with C and ε supplied by you; a compliant sizing also needs the coefficient correlation, the Reynolds number and the installation checks.
What is a typical discharge coefficient?
About 0.60–0.62 for a standard square-edged orifice inside the ISO limits, but take the value from the standard or the maker.
What is ε for water?
Exactly 1. Liquids are incompressible for this equation.
Why does flow follow the square root of Δp?
Because the pressure difference is proportional to the dynamic pressure, which goes with the square of velocity.
Can I use it for a Venturi or a nozzle?
The same equation form applies with the device’s own C and ε; the coefficients differ.