What the power numbers mean
A pump moves a liquid against a head. The hydraulic power is the energy per second actually given to the liquid, and the shaft power is what the pump needs at its efficiency:
- Ph = ρ·g·Q·H / 3.6e6 kW (Q m³/h, H m, ρ kg/m³)
- P = Ph / (η/100)
A pump delivering 100 m³/h at 20 m of water transfers 5.448 kW to the water. At 70 % efficiency the shaft needs 7.783 kW, and the motor must be sized above that with its own efficiency and a margin.
Head is metres of the pumped liquid
The head in metres is independent of density: 20 m of water and 20 m of a brine need the same head, but the brine needs more power because each cubic metre is heavier. That is why the same pump curve is quoted in metres and the power changes with the product. A density of 1200 kg/m³ raises the power by 20 %.
The affinity laws
For the same pump at a different speed, or a geometrically similar impeller diameter:
- Q₂/Q₁ = n₂/n₁
- H₂/H₁ = (n₂/n₁)²
- P₂/P₁ = (n₂/n₁)³
At 150 % speed the flow is 1.5×, the head 2.25× and the power 3.375×. At 80 % speed the power falls to 51 % — the reason variable-speed drives save so much energy on a throttled pump. The same relations apply to a trimmed impeller diameter, within the manufacturer’s allowable trim.
Worked example
100 m³/h at 20 m, η = 70 %, ρ = 1000 kg/m³:
- Ph = 1000 × 9.80665 × 100 × 20 / 3.6e6 = 5.448 kW
- Shaft = 5.448 / 0.70 = 7.783 kW
- At 120 % speed: Q = 120 m³/h, H = 28.8 m, P = 7.783 × 1.728 = 13.45 kW
The flow rate converter changes Q between units, and the control valve calculator sizes the valve that sets the duty point.
Where the laws stop
The affinity laws are exact only for similar points with unchanged efficiency. Away from the best efficiency point a real pump loses efficiency, the curves are not perfect parabolas, and NPSH margin changes with speed. They are a planning tool, not a substitute for the manufacturer’s curve.
Common mistakes
Using the cube law without checking the motor. Raising the speed by 20 % raises the power by 73 %; the existing motor may not cope.
Mixing gauge head and total head. The pump head includes the static lift, the pressure difference and the friction losses; use the total.
Forgetting density. A pump selected on water curves will draw more power on a heavier liquid, sometimes more than the motor rating.
Assuming the efficiency stays constant. A speed change moves the operating point; the efficiency at the new point must be read from the curve.
Frequently asked questions
Is hydraulic power the same as shaft power?
No. Hydraulic power is delivered to the liquid; shaft power is what the pump draws, larger by the efficiency.
Does density change the head?
No. The head in metres is the same; the pressure and the power change.
What is the affinity law for power?
P₂/P₁ = (n₂/n₁)³ for a speed change, and the same cube for an impeller diameter ratio.
Can I use the laws for a different pump?
Only for a geometrically similar pump or impeller. A different model needs its own curve.
Why does a VFD save energy?
Because power follows the cube of speed: at 80 % speed a centrifugal pump needs about half the power, if the system curve allows it.