What the ISO 10816-3 zones mean
ISO 10816-3 sorts the vibration of industrial machines into four zones by velocity RMS, measured on the bearing housings:
- Zone A: the level of a newly commissioned machine.
- Zone B: unrestricted long-term operation.
- Zone C: restricted operation; investigate before running for long.
- Zone D: vibration may damage the machine.
The boundaries depend on the machine group and on how stiffly the machine is supported, not on the sensor. The calculator applies the standard’s limits and shows the reading on the same scale, so the zone is visible at a glance.
Group 1 and group 2 machines
Group 1 covers large machines from 300 kW to 50 MW. Group 2 covers medium machines from 15 to 300 kW. Each group is split by support: rigid, where the first natural frequency is well above the running speed, and flexible, where it is not. The four boundaries are:
- Group 1, rigid: 2.3 / 4.5 / 7.1 mm/s
- Group 1, flexible: 3.5 / 7.1 / 11.0 mm/s
- Group 2, rigid: 1.4 / 2.8 / 4.5 mm/s
- Group 2, flexible: 2.3 / 4.5 / 7.1 mm/s
A reading exactly on a boundary belongs to the lower zone. The standard applies these limits to machines rated from 15 kW upward with speeds between 120 and 15000 rpm; pumps, fans, compressors, turbines and similar rotating machines are in scope.
Reading the zone on a measurement
Take the velocity RMS in the 10–1000 Hz band from a sensor mounted on the bearing housing. A magnet mount is acceptable for a screening check; a stud mount is better when the result will be used for a decision. Measure at rated load and speed, and record the direction (horizontal, vertical, axial) because the limits are applied to the highest of them.
The zone is a screening result: it says how the machine compares with the population the standard describes, not what is wrong with it. Two machines with the same zone can have very different faults.
What to do in zone C or D
Zone C calls for a shorter inspection interval and a look at the spectrum; zone D calls for immediate investigation and, if the trend is rising, a planned stop. In both cases the next step is the same: identify the frequency. A peak at shaft speed points to unbalance or misalignment, a peak at a bearing order to a bearing defect, and a broadband rise to looseness, cavitation or resonance. The bearing fault frequency calculator gives the orders for a known bearing geometry, and the vibration converter converts the reading between acceleration, velocity and displacement when the standard or the datasheet uses another quantity.
The 10–1000 Hz band
The limits are defined for velocity RMS in the 10–1000 Hz band. A measurement with a different band cannot be compared directly: 2–1000 Hz or 5–1000 Hz readings include low-frequency content the standard did not intend, and a 10–5000 Hz reading includes high-frequency energy that inflates the velocity RMS. Set the analyser to the standard’s band before comparing a number with the table.
ISO 10816-3 and ISO 20816
ISO 10816-3 has been superseded by the ISO 20816 series. ISO 20816-3 keeps the zone concept and revises some limits and machine groupings. Many installed systems still refer to 10816-3, so this page states those values and says so on the method line; when a plant standard names the newer edition, use its table instead.
Common mistakes
Comparing a peak velocity with the RMS limit. The limits are RMS. A peak reading of 2.8 mm/s is not zone B at the same boundary; convert first, or measure RMS.
Using the wrong group. A 200 kW motor is group 2, a 400 kW motor is group 1. The difference moves every boundary.
Ignoring the support. The same machine on a stiff foundation and on a flexible frame belongs to different columns of the table.
Measuring on the motor end bell or a guard. The limits assume the bearing housing; a thin cover amplifies or attenuates the reading unpredictably.
Frequently asked questions
Is zone B acceptable?
Yes, for unrestricted long-term operation. Zone C is the level at which the standard asks for restricted operation and an investigation, and zone D for immediate action.
What does “rigid support” mean?
A support whose first natural frequency is clearly above the running speed, so the machine does not amplify the running-speed vibration. A concrete block is typical; a light steel frame is usually flexible.
Can I use the calculator for a 5.5 kW motor?
The 10816-3 table covers machines from 15 kW. Below that, the standard refers to other parts of the series; the calculator’s group 2 numbers are not a drop-in replacement.
Which direction should I measure?
The highest of horizontal, vertical and axial on each bearing housing, with the machine at rated load and speed.
Why does the reading differ from the manufacturer’s acceptance value?
The limits are for velocity RMS in 10–1000 Hz at the bearing housing. Different bands, mounts or operating points change the number; compare like with like.
Does a zone D reading mean the machine will fail?
No, it means the vibration is high enough that damage is possible. The trend, the frequency content and the machine history decide what to do next.
Is ISO 10816-3 still current?
It has been superseded by ISO 20816-3, which keeps the zone idea. Many plants still quote 10816-3 limits; check which edition the specification names.