ISO 11898-22-wire Twisted Pair (CANH / CANL)

CAN / CANopen Bus Split Termination & Differential Levels

ISO 11898 Differential Dominant/Recessive · 3.3 V / 5.0 V Transceiver

Terminate both physical ends of an ISO 11898 CAN bus with 120 Ω (60 Ω measured DC) — ideally using 60 Ω + 60 Ω + 4.7 nF split termination to shunt high-frequency common-mode EMI to ground.

CAN DOMINANT OK — V_diff = 2.00 V · R_bus = 60 Ω

Split termination (2 × 60 Ω + 4.7 nF) shunts common-mode noise above 1129 kHz while holding 60 Ω differential match.

Normal current flowWarning / ClampFault / OvercurrentFlow speed ∝ current |I|
CAN Node 1TJA1051 / TCAN2.00 V12 NodesCANH = 3.50 VCANL = 1.50 V60 Ω60 Ω4.7 nF60 Ω60 Ω4.7 nF⚠ CANH-CANL SHORT!CAN SensorCANopen / J19392.00 VISO 11898-2

Differential V_diff

2.00 V

DC Bus Resistance

60 Ω

CM Filter Cutoff

1129 kHz

Driver Bus Current

33.3 mA

CANH Voltage3.50 V
CANL Voltage1.50 V
Termination Match60 Ω Matched
Ω

ISO 11898 requires 120 Ω at both physical ends (60 Ω + 60 Ω for split).

nF

Standard 4.7 nF (100 V X7R) shunts common-mode RF noise to GND.

nodes

Standard transceivers support 32–110 nodes on a 120 Ω twisted pair.

Presets:

Live Step-by-Step Formulas

Split-Termination Common-Mode Cutoff

f_CM = 1 / (2π · (Rt / 4) · C_split) = 1 / (2π × 30.0 Ω × 4.7 nF)

⇒ 1128.8 kHz

Differential Bus Load Resistance

R_bus = Rt ∥ Rt = Rt / 2 = 120 Ω / 2

⇒ 60 Ω

Dynamic BOM & Component Sizing

RefComponentCalculated RatingCheck
R1–R41% 60.4 Ω (0805) Split Terminators2 per bus end (120 Ω total)OK
C_split4.7 nF 100 V X7R CapacitorMidpoint to GND for EMI bypassOK
D_CANPESD2CAN / NUP2105L Dual TVS±24 V standoff, <15 pFOK

1. Engineering Overview & How the Circuit Works

CAN / CANopen / J1939 (ISO 11898-2) is the dominant real-time bus for industrial robotics, mobile machinery, and automotive sensors. Proper 120 Ω termination at BOTH physical ends (60 Ω DC bus resistance) prevents reflections, while Split Termination (60 Ω + 60 Ω + 4.7 nF to GND) dramatically improves EMC common-mode noise rejection.

Dominant vs Recessive Signaling: In Recessive (logic 1), drivers release the bus to 2.5 V / 2.5 V (V_diff = 0 V). In Dominant (logic 0), a transmitter pulls CANH to ~3.5 V and CANL to ~1.5 V (V_diff ≈ 2.0 V) across the 60 Ω parallel termination load.

Split Termination EMC Magic: Splitting each 120 Ω into two 60 Ω resistors with a 4.7 nF capacitor from the center tap to GND leaves the 120 Ω differential impedance unchanged while forming a ~1.1 MHz low-pass filter that shunts high-frequency common-mode RF noise straight to ground!

CAN / CANopen Bus Split Termination & Differential Levels — SensorCatalog
CAN Bus Split TerminationPNG 1200×630

2. Step-by-step: Terminating and commissioning an ISO 11898 CAN sensor bus

  1. 1Verify 60 Ω across CANH–CANL with power OFF

    120 Ω means one end is missing; 40 Ω means a middle node accidentally left its terminator enabled!

  2. 2Use 60.4 Ω + 60.4 Ω + 4.7 nF (100 V X7R) split termination

    Rate the split capacitor ≥ 100 V so it survives industrial bus-to-ground transients.

  3. 3Keep stub lengths < 0.3 m at 1 Mbps

    Always daisy-chain sensor drops rather than star-wiring from a junction box.

  4. 4Add low-capacitance CAN ESD protection (PESD2CAN)

    Keep TVS capacitance < 15 pF so high-speed 1 Mbps / CAN-FD edges stay crisp.

3. Field Troubleshooting & Multimeter Diagnostics

SymptomRoot CauseMultimeter CheckCorrective Fix
CAN works at 125 kbps but drops into Bus-Off at 500 kbps or 1 MbpsMissing second 120 Ω terminator or excessive star-wired stub lengthMeasure power-off CANH–CANL resistance (should be ~60 Ω) and probe Dominant edgesInstall matched 60+60 Ω split terminators at both physical cable ends only

4. Frequently Asked Engineering Questions

Why do I measure 60 Ω instead of 120 Ω on a healthy CAN bus?

Because two 120 Ω terminators — one at each physical end of the bus — sit in parallel: 120 Ω || 120 Ω = 60 Ω.