SensorCatalog
ISO 11898-22-wire Twisted Pair (CANH / CANL)

CAN / CANopen 버스 종단 · 스플릿 종단(60+60 Ω + 4.7 nF)

ISO 11898 Differential Dominant/Recessive · 3.3 V / 5.0 V Transceiver

ISO 11898 CAN 버스 양단에 120 Ω(합성 60 Ω)을 종단하며, 60 Ω + 60 Ω + 4.7 nF 스플릿 종단으로 고주파 공통모드 노이즈를 접지로 바이패스합니다.

CAN DOMINANT OK — V_diff = 2.00 V · R_bus = 60 Ω

Split termination (2 × 60 Ω + 4.7 nF) shunts common-mode noise above 1129 kHz while holding 60 Ω differential match.

정상 전류 흐름경고 / 클램프고장 / 과전류속도 ∝ 전류 |I|
CAN Node 1TJA1051 / TCAN2.00 V12 NodesCANH = 3.50 VCANL = 1.50 V60 Ω60 Ω4.7 nF60 Ω60 Ω4.7 nF⚠ CANH-CANL SHORT!CAN SensorCANopen / J19392.00 VISO 11898-2

Differential V_diff

2.00 V

DC Bus Resistance

60 Ω

CM Filter Cutoff

1129 kHz

Driver Bus Current

33.3 mA

CANH Voltage3.50 V
CANL Voltage1.50 V
Termination Match60 Ω Matched
Ω

ISO 11898 requires 120 Ω at both physical ends (60 Ω + 60 Ω for split).

nF

Standard 4.7 nF (100 V X7R) shunts common-mode RF noise to GND.

nodes

Standard transceivers support 32–110 nodes on a 120 Ω twisted pair.

프리셋:

실시간 단계별 수식

Split-Termination Common-Mode Cutoff

f_CM = 1 / (2π · (Rt / 4) · C_split) = 1 / (2π × 30.0 Ω × 4.7 nF)

⇒ 1128.8 kHz

Differential Bus Load Resistance

R_bus = Rt ∥ Rt = Rt / 2 = 120 Ω / 2

⇒ 60 Ω

동적 부품 선정 및 BOM

부호부품계산 정격상태
R1–R41% 60.4 Ω (0805) Split Terminators2 per bus end (120 Ω total)OK
C_split4.7 nF 100 V X7R CapacitorMidpoint to GND for EMI bypassOK
D_CANPESD2CAN / NUP2105L Dual TVS±24 V standoff, <15 pFOK

1. 회로 개요 및 동작 원리

CAN / CANopen / J1939 (ISO 11898-2) is the dominant real-time bus for industrial robotics, mobile machinery, and automotive sensors. Proper 120 Ω termination at BOTH physical ends (60 Ω DC bus resistance) prevents reflections, while Split Termination (60 Ω + 60 Ω + 4.7 nF to GND) dramatically improves EMC common-mode noise rejection.

Dominant vs Recessive Signaling: In Recessive (logic 1), drivers release the bus to 2.5 V / 2.5 V (V_diff = 0 V). In Dominant (logic 0), a transmitter pulls CANH to ~3.5 V and CANL to ~1.5 V (V_diff ≈ 2.0 V) across the 60 Ω parallel termination load.

Split Termination EMC Magic: Splitting each 120 Ω into two 60 Ω resistors with a 4.7 nF capacitor from the center tap to GND leaves the 120 Ω differential impedance unchanged while forming a ~1.1 MHz low-pass filter that shunts high-frequency common-mode RF noise straight to ground!

CAN / CANopen 버스 종단 · 스플릿 종단(60+60 Ω + 4.7 nF) — SensorCatalog
CAN 스플릿 종단PNG 1200×630

2. Step-by-step: Terminating and commissioning an ISO 11898 CAN sensor bus

  1. 1Verify 60 Ω across CANH–CANL with power OFF

    120 Ω means one end is missing; 40 Ω means a middle node accidentally left its terminator enabled!

  2. 2Use 60.4 Ω + 60.4 Ω + 4.7 nF (100 V X7R) split termination

    Rate the split capacitor ≥ 100 V so it survives industrial bus-to-ground transients.

  3. 3Keep stub lengths < 0.3 m at 1 Mbps

    Always daisy-chain sensor drops rather than star-wiring from a junction box.

  4. 4Add low-capacitance CAN ESD protection (PESD2CAN)

    Keep TVS capacitance < 15 pF so high-speed 1 Mbps / CAN-FD edges stay crisp.

3. 현장 트러블슈팅 및 멀티미터 점검

증상근본 원인멀티미터 점검조치 방법
CAN works at 125 kbps but drops into Bus-Off at 500 kbps or 1 MbpsMissing second 120 Ω terminator or excessive star-wired stub lengthMeasure power-off CANH–CANL resistance (should be ~60 Ω) and probe Dominant edgesInstall matched 60+60 Ω split terminators at both physical cable ends only

4. 자주 묻는 엔지니어링 질문 (FAQ)

Why do I measure 60 Ω instead of 120 Ω on a healthy CAN bus?

Because two 120 Ω terminators — one at each physical end of the bus — sit in parallel: 120 Ω || 120 Ω = 60 Ω.

5. 관련 계산기, 비교 가이드 및 다른 센서 회로