SensorCatalog

PT1000 calculator

A PT1000 measures 1,000 Ω at 0 °C and 1,385.06 Ω at 100 °C (IEC 60751) — ten times a PT100, so lead-wire error shrinks tenfold. Type in either field.

A PT1000 is 1000 Ω at 0 °C and 1385.055 Ω at 100 °C (IEC 60751, α = 0.00385). That is ten times the PT100 resistance and ten times its slope, so the same lead resistance costs a tenth of the temperature error.

Element

CurveIEC 60751, α = 0.00385, R₀ = 1000 Ω

Convert

Result

Sensitivity
3.7928 Ω/°CR/R₀ = 1.38506
Class AA tolerance
±0.27 °C±1.02 Ω
Class A tolerance
±0.35 °C±1.33 Ω
Class B tolerance
±0.80 °C±3.03 Ω
Against PT100
×100.3793 Ω/°C · PT100 sensitivity

Table

Temperature (°C)Resistance (Ω)Sensitivity (Ω/°C)
-50803.063.9713
-49807.033.9699
-48811.003.9685
-47814.973.9671
-46818.943.9657
-45822.903.9643
-44826.873.9630
-43830.833.9616
-42834.793.9603
-41838.753.9589
-40842.713.9576
-39846.663.9562
-38850.623.9549
-37854.573.9536
-36858.533.9523
-35862.483.9510
-34866.433.9497
-33870.383.9484
-32874.323.9471
-31878.273.9458
-30882.223.9445
-29886.163.9433
-28890.103.9420
-27894.043.9407
-26897.983.9395
-25901.923.9382
-24905.863.9370
-23909.803.9357
-22913.733.9345
-21917.673.9333
-20921.603.9320
-19925.533.9308
-18929.463.9296
-17933.393.9284
-16937.323.9272
-15941.243.9260
-14945.173.9248
-13949.093.9236
-12953.023.9224
-11956.943.9212
-10960.863.9200
-9964.783.9188
-8968.703.9176
-7972.613.9165
-6976.533.9153
-5980.443.9141
-4984.363.9129
-3988.273.9118
-2992.183.9106
-1996.093.9095
01000.003.9083
11003.913.9071
21007.813.9060
31011.723.9048
41015.623.9037
51019.533.9025
61023.433.9014
71027.333.9002
81031.233.8991
91035.133.8979
101039.033.8968
111042.923.8956
121046.823.8944
131050.713.8933
141054.603.8921
151058.493.8910
161062.383.8898
171066.273.8887
181070.163.8875
191074.053.8864
201077.943.8852
211081.823.8840
221085.703.8829
231089.593.8817
241093.473.8806
251097.353.8794
261101.233.8783
271105.103.8771
281108.983.8760
291112.863.8748
301116.733.8737
311120.603.8725
321124.473.8713
331128.353.8702
341132.213.8690
351136.083.8679
361139.953.8667
371143.823.8656
381147.683.8644
391151.553.8633
401155.413.8621
411159.273.8609
421163.133.8598
431166.993.8586
441170.853.8575
451174.703.8563
461178.563.8552
471182.413.8540
481186.273.8529
491190.123.8517
501193.973.8506
511197.823.8494
521201.673.8482
531205.523.8471
541209.363.8459
551213.213.8448
561217.053.8436
571220.903.8425
581224.743.8413
591228.583.8402
601232.423.8390
611236.263.8378
621240.093.8367
631243.933.8355
641247.773.8344
651251.603.8332
661255.433.8321
671259.263.8309
681263.093.8298
691266.923.8286
701270.753.8275
711274.583.8263
721278.403.8251
731282.233.8240
741286.053.8228
751289.873.8217
761293.703.8205
771297.523.8194
781301.333.8182
791305.153.8171
801308.973.8159
811312.783.8147
821316.603.8136
831320.413.8124
841324.223.8113
851328.033.8101
861331.843.8090
871335.653.8078
881339.463.8067
891343.263.8055
901347.073.8044
911350.873.8032
921354.683.8020
931358.483.8009
941362.283.7997
951366.083.7986
961369.873.7974
971373.673.7963
981377.473.7951
991381.263.7940
1001385.063.7928
1011388.853.7916
1021392.643.7905
1031396.433.7893
1041400.223.7882
1051404.003.7870
1061407.793.7859
1071411.583.7847
1081415.363.7836
1091419.143.7824
1101422.933.7813
1111426.713.7801
1121430.493.7789
1131434.263.7778
1141438.043.7766
1151441.823.7755
1161445.593.7743
1171449.373.7732
1181453.143.7720
1191456.913.7709
1201460.683.7697
1211464.453.7685
1221468.223.7674
1231471.983.7662
1241475.753.7651
1251479.513.7639
1261483.283.7628
1271487.043.7616
1281490.803.7605
1291494.563.7593
1301498.323.7582
1311502.083.7570
1321505.833.7558
1331509.593.7547
1341513.343.7535
1351517.103.7524
1361520.853.7512
1371524.603.7501
1381528.353.7489
1391532.103.7478
1401535.843.7466
1411539.593.7454
1421543.333.7443
1431547.083.7431
1441550.823.7420
1451554.563.7408
1461558.303.7397
1471562.043.7385
1481565.783.7374
1491569.523.7362
1501573.253.7351
1511576.993.7339
1521580.723.7327
1531584.453.7316
1541588.183.7304
1551591.913.7293
1561595.643.7281
1571599.373.7270
1581603.093.7258
1591606.823.7247
1601610.543.7235
1611614.273.7223
1621617.993.7212
1631621.713.7200
1641625.433.7189
1651629.153.7177
1661632.863.7166
1671636.583.7154
1681640.303.7143
1691644.013.7131
1701647.723.7120
1711651.433.7108
1721655.143.7096
1731658.853.7085
1741662.563.7073
1751666.273.7062
1761669.973.7050
1771673.683.7039
1781677.383.7027
1791681.083.7016
1801684.783.7004
1811688.483.6992
1821692.183.6981
1831695.883.6969
1841699.583.6958
1851703.273.6946
1861706.963.6935
1871710.663.6923
1881714.353.6912
1891718.043.6900
1901721.733.6889
1911725.423.6877
1921729.103.6865
1931732.793.6854
1941736.483.6842
1951740.163.6831
1961743.843.6819
1971747.523.6808
1981751.203.6796
1991754.883.6785
2001758.563.6773

Click a row to load it into the converter.

Schematic

Resistance / Ω39040−200850Temperature / °CT100 °CR1385.06 Ω
Drawn from the inputs above; not to scale.
Formulas and standards
R(t) = 1000 [1 + A·t + B·t² + C·(t − 100)·t³]

A PT1000 is the same platinum curve as a PT100 with R₀ = 1000 Ω instead of 100 Ω: ten times the resistance and ten times the sensitivity, so a given lead resistance costs a tenth of the temperature error. Resistance to temperature is solved by the same inverse function as the PT100 calculator, with a residual below 1e−6 °C over the whole range.

A = 3.9083 × 10⁻³, B = −5.775 × 10⁻⁷, C = −4.183 × 10⁻¹² below 0 °C and 0 above. Valid from −200 to 850 °C. Resistance to temperature is solved exactly above 0 °C and by Newton iteration below.

Tolerance classes: AA ±(0.10 + 0.0017|t|), A ±(0.15 + 0.002|t|), B ±(0.30 + 0.005|t|), C ±(0.6 + 0.01|t|) °C. The range each class applies over depends on wire-wound or thin-film construction. Shown values use wire-wound limits: AA −50…250 °C, A −100…450 °C, B/C −196…600 °C. Thin-film limits: AA 0…150 °C, A −30…300 °C, B −50…500 °C, C −50…600 °C. Check the element datasheet.

Looking for PT1000 probes, thin-film elements or RTD transmitters?

Contact us

How the PT1000 calculator works

A PT1000 is a platinum resistance thermometer with 1000 Ω at 0 °C. It follows the same Callendar–Van Dusen curve as a PT100, per IEC 60751, with α = 0.00385:

  • Above 0 °C: R(t) = 1000 × (1 + A·t + B·t²)
  • Below 0 °C: R(t) = 1000 × (1 + A·t + B·t² + C·(t − 100)·t³), with A = 3.9083 × 10⁻³, B = −5.775 × 10⁻⁷ and C = −4.183 × 10⁻¹²

The calculator converts in both directions. Type a temperature to get the resistance, or a resistance to get the temperature; the last field you edit is the input. Resistance to temperature is solved by the same inverse function as the PT100 calculator, not by a lookup table, so the answer is exact for the IEC curve to better than 10⁻⁶ °C.

The valid range is −200 to 850 °C, the range IEC 60751 defines for platinum elements. Outside it the calculator says so instead of returning a made-up number.

Worked examples

  • 0 °C → 1000.000 Ω
  • 100 °C → 1385.055 Ω, usually shown as 1385.06 Ω
  • −50 °C → 803.063 Ω
  • 200 °C → 1758.560 Ω
  • 850 °C → 3904.811 Ω

In reverse, 1385.055 Ω returns 100 °C. Each degree near room temperature changes the resistance by about 3.9 Ω, which is why a two-wire PT1000 tolerates cable resistance far better than a PT100.

PT1000 vs PT100: same curve, ten times the resistance

Both elements are platinum and both use α = 0.00385. The PT1000 is exactly ten times the resistance at every temperature, so its sensitivity is also ten times higher: 3.9083 Ω/°C at 0 °C against 0.39083 Ω/°C for the PT100.

That matters for lead resistance. A 10 m run of 0.5 mm² copper has about 0.344 Ω per conductor at 20 °C, so a two-wire loop adds 0.688 Ω. On a PT1000 at 100 °C that is 0.688 / 3.7928 ≈ 0.18 °C of error. On a PT100 at the same temperature it is 0.688 / 0.37928 ≈ 1.81 °C, ten times worse. The RTD lead-wire error calculator compares 2-, 3- and 4-wire connection for both elements.

The comparison is not all in the PT1000’s favour: for the same current it dissipates ten times the power (P = I²R), so self-heating is the thing to watch in still air. Many transmitters therefore excite a PT1000 with a smaller current than a PT100, and the temperature rise must be read from the probe datasheet, not guessed.

Where the PT1000 is the better choice

  • Long cable runs and two-wire connections, where the higher resistance swamps the lead resistance.
  • Thin-film elements in small probes and surface sensors, where a sturdy 100 Ω wire-wound element does not fit.
  • Battery, EV and electronics work, where the higher signal suits low-power ADCs and simple dividers.
  • Applications where the same transmitter must accept both elements: PT1000 reaches the same resolution with less current.

A PT100 remains the better choice where the extra resistance makes matching harder, or where the installed base and spares are PT100. At the same tolerance class, the two elements have the same accuracy in °C; only the wiring error and the self-heating change.

Wiring and self-heating

A two-wire connection puts both leads in series with the element; a three-wire connection subtracts one lead if all three are equal; a four-wire connection keeps the current loop separate from the voltage sense and removes lead resistance almost completely. Above a few metres, three- or four-wire is the safe choice even with a PT1000.

Self-heating is the product of the current squared and the element resistance. At 1 mA a PT1000 at 100 °C dissipates about 1.4 mW. The temperature rise per milliwatt is a property of the probe (its dissipation coefficient), so check the datasheet; in a small thin-film sensor it can be a few tenths of a kelvin per milliwatt.

Tolerance classes

IEC 60751 defines the tolerance classes by a fixed term plus a slope term:

  • Class AA: ±(0.10 + 0.0017 × |t|) °C
  • Class A: ±(0.15 + 0.002 × |t|) °C
  • Class B: ±(0.30 + 0.005 × |t|) °C
  • Class C: ±(0.6 + 0.01 × |t|) °C

At 100 °C, class A allows ±0.35 °C, which is ±1.33 Ω on a PT1000. The range over which each class is defined depends on wire-wound or thin-film construction; the calculator shows the wire-wound limits and the datasheet decides the rest.

Common mistakes

Assuming a PT1000 is ten times more accurate. It is not. The tolerance is specified in °C and is the same as the PT100 of the same class. What improves is the lead-resistance error.

Reading a PT100 table for a PT1000. Every value is ten times larger. Use the PT1000 resistance table or the calculator, and check the column heading before writing a value into a transmitter.

Using two wires on a long run. A PT1000 hides the error better, but it does not remove it. Above a few metres, use three or four wires.

Ignoring self-heating. The higher resistance makes the same excitation current dissipate more power. If the probe sits in still air, compare the datasheet’s dissipation coefficient with the power the transmitter delivers.

Expecting a linear output. The curve is close to linear near room temperature, but it is not a straight line; at 850 °C the sensitivity has fallen to about 3.2 Ω/°C. Use the curve, not a single slope.

Frequently asked questions

Is a PT1000 more accurate than a PT100?

At the same tolerance class, no: both are specified to the same ±°C limits. The PT1000 is more accurate in a two-wire circuit because its higher resistance makes the lead error ten times smaller.

What is the resistance of a PT1000 at 100 °C?

1385.055 Ω per IEC 60751 (α = 0.00385). The calculator and the reference table show 1385.06 Ω when rounded to two decimals.

Can I use a PT1000 with a PT100 transmitter?

Only if the transmitter can be configured for 1000 Ω. Many temperature transmitters and PLC cards accept both, but the input type must be set correctly; a PT1000 read as a PT100 shows a large negative error.

Why is the PT1000 preferred for long cables?

Because its sensitivity is ten times higher, the same lead resistance produces a tenth of the temperature error. A three-wire connection removes most of the remainder.

How much current should excite a PT1000?

As little as the transmitter allows while keeping a usable signal. 0.1 to 1 mA is typical; at 1 mA the element dissipates about 1 mW at 100 °C, and the resulting rise depends on the probe.

Does the calculator work below 0 °C?

Yes, down to −200 °C. The C coefficient is applied below 0 °C exactly as IEC 60751 defines it.

Which tolerance class should I order?

Class A or AA for process and laboratory measurements, class B for general monitoring. Check the temperature range over which the class is defined, and the construction of the element.

↑ ↓ choose · Enter open · Esc close