SensorCatalog
IEC 61000-4-52-wire 24 V Industrial Power Entry

24 V 産業用センサ電源保護(PMOS 逆接防止・TVS・PTC)

Protected DC Power Bus · 10–36 V DC Industrial Rail

PTC ヒューズ、後段 SMBJ28A TVS、12 V ゲート保護ツェナー付き PMOS により、逆接・サージ・短絡を数 mV の低損失で防御します。

POWER ENTRY PROTECTED — V_out = 23.94 V · V_gs = -12.0 V

PMOS drops only 6.8 mV (1.0 mW vs 105 mW for a diode!), while D_Z clamps V_gs safely at -12.0 V.

正常電流フロー警告・クランプ故障・過電流速度 ∝ 電流 |I|
Field Input+24.0 V0 V (GND)PTC500 mAPTC TRIPPED!SMBJ28A TVSPMOS Q1Vgs=-12.0V100 kΩ12V ZProtected Rail23.94 V150 mADC-DC / LDO / MCU

Protected Bus V_out

23.94 V

PMOS Gate V_gs

-12.0 V

PMOS Dissipation

1.0 mW

PTC Trip Threshold

1000 mA

PTC FuseOK (I_hold 500mA)
SMBJ28A TVSStandby
PMOS Q1ON (Conducting)
V

Industrial 24 V rail (typically 18–30 V DC).

mA

Normal operating current draw of the protected module.

mΩ

e.g. AO3401 / SI4435 / SQJ403EP (20–100 mΩ).

mA

Must exceed 1.5× max load current; trips reliably at ~2× I_hold.

プリセット:

リアルタイム計算式

PMOS Conduction Loss vs Schottky Diode

P_PMOS = I_load² × Rds_on = (0.150 A)² × 45 mΩ

⇒ 1.01 mW

Zener Gate Clamp Protection

|V_gs| = min(V_zener, V_in) ≤ 20 V = min(12.0 V, 24.0 V)

⇒ 12.0 V (Safe)

動的部品選定・BOM

記号部品推奨定格判定
F11812 Polymeric PTC FuseI_hold = 500 mA, 36 VOK
D1SMBJ28A Unidirectional TVSVrwm = 28 V, Vc = 45.4 VOK
Q1 / DZ−40 V PMOS + 12 V ZenerRds_on = 45 mΩ + 100 kΩOK

1. 回路概要と動作原理

Every 24 V industrial sensor module or PLC expansion board must survive three field realities: reversed power wiring (−24 V), relay/motor inductive surges (+40–60 V), and downstream short circuits. Combining a polymeric PTC fuse, SMBJ28A TVS, and a P-channel MOSFET with a 12 V Zener gate clamp delivers bulletproof protection with millivolt drop.

Why PMOS Beats a Diode: A 1N4007 or Schottky diode wastes 0.5–0.8 V and heats up at high current. A back-wired PMOS (drain to input, source to load) conducts through its 45 mΩ channel during normal polarity (only ~7 mV drop at 150 mA!) yet blocks −24 V completely when reversed.

Mandatory 12 V Zener Gate Clamp: Most PMOS gates rupture above ±20 V! On a 24 V industrial rail (plus 38 V TVS surges), tying Gate directly to GND destroys Q1 immediately. Placing a 12 V Zener between Gate and Source + 100 kΩ to GND locks Vgs safely at −12 V.

24 V 産業用センサ電源保護(PMOS 逆接防止・TVS・PTC) — SensorCatalog
24 V 電源入口保護PNG 1200×630

2. Step-by-step: Building a bulletproof 24 V sensor power entry stage

  1. 1Size PTC I_hold ≥ 1.8× max load to survive 60 °C cabinets

    Polymeric PTC fuses derate by ~30% at 60 °C ambient; undersizing causes mysterious random resets.

  2. 2Select SMBJ28A TVS (Vrwm = 28 V) after the PTC

    Place TVS AFTER the PTC so sustained overvoltage trips the PTC instead of exploding the TVS.

  3. 3Orient PMOS Source toward the load and Drain toward input

    Verify body diode anode faces Drain so forward power starts conduction and reverse polarity blocks!

  4. 4Add 12 V Zener across G–S + 100 kΩ gate resistor

    Use a −40 V or −60 V rated PMOS so it survives the ~38–45 V clamping peak of the SMBJ28A.

3. 現場トラブルシューティングとテスタ確認

症状原因テスタ測定ポイント対策
PMOS shorts out permanently on first 24 V power-upMissing 12 V Zener clamp — 24 V exceeded PMOS ±20 V Vgs(max) ratingMeasure Gate-to-Source resistance (often <10 Ω after gate punch-through)Install 12 V Zener (BZT52C12) across G–S and 100 kΩ to GND

4. よくある技術質問(FAQ)

Why put the TVS diode after the PTC instead of before it?

If someone applies a continuous 36 V overvoltage, the TVS conducts heavily; placing the PTC upstream lets the PTC trip and protect the TVS from burning up.

5. 関連計算ツール・比較ガイド・その他の回路

↑ ↓ 選択 · Enter 開く · Esc 閉じる