SensorCatalog
IEC 61000-4-52-wire 24 V Industrial Power Entry

Protection Entrée Alimentation 24 V (PMOS, TVS & Fusible PTC)

Protected DC Power Bus · 10–36 V DC Industrial Rail

Protégez les cartes capteurs 24 V par fusible PTC, TVS SMBJ28A en aval et PMOS high-side avec Zener 12 V grille-source (Vgs sûr sous ±20 V).

POWER ENTRY PROTECTED — V_out = 23.94 V · V_gs = -12.0 V

PMOS drops only 6.8 mV (1.0 mW vs 105 mW for a diode!), while D_Z clamps V_gs safely at -12.0 V.

Courant normalAlerte / ÉcrêtageDéfaut / SurintensitéVitesse ∝ |I|
Field Input+24.0 V0 V (GND)PTC500 mAPTC TRIPPED!SMBJ28A TVSPMOS Q1Vgs=-12.0V100 kΩ12V ZProtected Rail23.94 V150 mADC-DC / LDO / MCU

Protected Bus V_out

23.94 V

PMOS Gate V_gs

-12.0 V

PMOS Dissipation

1.0 mW

PTC Trip Threshold

1000 mA

PTC FuseOK (I_hold 500mA)
SMBJ28A TVSStandby
PMOS Q1ON (Conducting)
V

Industrial 24 V rail (typically 18–30 V DC).

mA

Normal operating current draw of the protected module.

mΩ

e.g. AO3401 / SI4435 / SQJ403EP (20–100 mΩ).

mA

Must exceed 1.5× max load current; trips reliably at ~2× I_hold.

Préréglages :

Formules pas à pas en direct

PMOS Conduction Loss vs Schottky Diode

P_PMOS = I_load² × Rds_on = (0.150 A)² × 45 mΩ

⇒ 1.01 mW

Zener Gate Clamp Protection

|V_gs| = min(V_zener, V_in) ≤ 20 V = min(12.0 V, 24.0 V)

⇒ 12.0 V (Safe)

Nomenclature dynamique (BOM)

Réf.ComposantCalibrage calculéÉtat
F11812 Polymeric PTC FuseI_hold = 500 mA, 36 VOK
D1SMBJ28A Unidirectional TVSVrwm = 28 V, Vc = 45.4 VOK
Q1 / DZ−40 V PMOS + 12 V ZenerRds_on = 45 mΩ + 100 kΩOK

1. Présentation & principe de fonctionnement

Every 24 V industrial sensor module or PLC expansion board must survive three field realities: reversed power wiring (−24 V), relay/motor inductive surges (+40–60 V), and downstream short circuits. Combining a polymeric PTC fuse, SMBJ28A TVS, and a P-channel MOSFET with a 12 V Zener gate clamp delivers bulletproof protection with millivolt drop.

Why PMOS Beats a Diode: A 1N4007 or Schottky diode wastes 0.5–0.8 V and heats up at high current. A back-wired PMOS (drain to input, source to load) conducts through its 45 mΩ channel during normal polarity (only ~7 mV drop at 150 mA!) yet blocks −24 V completely when reversed.

Mandatory 12 V Zener Gate Clamp: Most PMOS gates rupture above ±20 V! On a 24 V industrial rail (plus 38 V TVS surges), tying Gate directly to GND destroys Q1 immediately. Placing a 12 V Zener between Gate and Source + 100 kΩ to GND locks Vgs safely at −12 V.

Protection Entrée Alimentation 24 V (PMOS, TVS & Fusible PTC) — SensorCatalog
Protection Entrée 24 VPNG 1200×630

2. Step-by-step: Building a bulletproof 24 V sensor power entry stage

  1. 1Size PTC I_hold ≥ 1.8× max load to survive 60 °C cabinets

    Polymeric PTC fuses derate by ~30% at 60 °C ambient; undersizing causes mysterious random resets.

  2. 2Select SMBJ28A TVS (Vrwm = 28 V) after the PTC

    Place TVS AFTER the PTC so sustained overvoltage trips the PTC instead of exploding the TVS.

  3. 3Orient PMOS Source toward the load and Drain toward input

    Verify body diode anode faces Drain so forward power starts conduction and reverse polarity blocks!

  4. 4Add 12 V Zener across G–S + 100 kΩ gate resistor

    Use a −40 V or −60 V rated PMOS so it survives the ~38–45 V clamping peak of the SMBJ28A.

3. Dépannage terrain & mesures au multimètre

SymptômeCause racineContrôle multimètreAction corrective
PMOS shorts out permanently on first 24 V power-upMissing 12 V Zener clamp — 24 V exceeded PMOS ±20 V Vgs(max) ratingMeasure Gate-to-Source resistance (often <10 Ω after gate punch-through)Install 12 V Zener (BZT52C12) across G–S and 100 kΩ to GND

4. Questions fréquentes (FAQ)

Why put the TVS diode after the PTC instead of before it?

If someone applies a continuous 36 V overvoltage, the TVS conducts heavily; placing the PTC upstream lets the PTC trip and protect the TVS from burning up.

5. Calculateurs associés, guides et autres circuits

↑ ↓ choisir · Entrée ouvrir · Échap fermer