SensorCatalog
IEC 600514-Terminal Kelvin Shunt → CSA

Amplificateur Shunt de Courant High-Side vs Low-Side (Kelvin)

High-CMRR mV Shunt Amplification · 5–48 V Bus · 3.3/5 V Amp

La mesure High-Side (INA240 + shunt 4 bornes) garde la charge à la vraie masse 0 V et détecte les courts-circuits châssis, tandis que le Low-Side soulève la masse de +Iload × Rs.

HIGH-SIDE KELVIN: 10.0 A × 10 mΩ × 20× = 2.000 V (Load GND = 0.00 V)

INA240 rejects +24 V common-mode cleanly (>120 dB CMRR). Shunt heat is 1.00 W.

Courant normalAlerte / ÉcrêtageDéfaut / SurintensitéVitesse ∝ |I|
DC Bus+24 V10.0 A0 V (Chassis)Rs = 10 mΩ (1.00 W)100.0 mVMotor / LoadGND: 0.00 V4-Term Kelvin Sense Pair⚠ NON-KELVIN: +3.5 mΩ COPPER TRACE ERROR!INA240 / INA180Current-Sense Amp2.00 VV_out = G · I_load · R_s

Amplifier Output (Vout)

2.000 V

Shunt Voltage Drop

100.0 mV

Shunt Power Dissipation

1.00 W

Load Ground Bounce

+0 mV

Shunt PlacementHIGH-SIDE (+24 V Bus)
Kelvin 4-Terminal RoutingTRUE KELVIN (0% Trace Err)
Chassis Short DetectionPROTECTED (Detects All Faults)
Shunt Thermal RatingSAFE (1.00 W)
A

DC motor, solenoid, or battery pack current (0.5–50 A).

mΩ

Target 50–100 mV full-scale drop to balance SNR vs I²R heat.

×

INA240 / INA180 fixed gains: 20×, 50×, 100×, 200×.

V

High-side amps survive up to 26–80 V common-mode independently of 3.3 V supply!

Préréglages :

Formules pas à pas en direct

1. Shunt sense voltage

V_sense = I_load · (R_s + R_trace) = 10.0 A × 10.0 mΩ

⇒ 100.00 mV

2. Amplified output voltage

V_out = G · V_sense = 20 × 100.00 mV

⇒ 2.000 V

3. Shunt thermal dissipation

P_s = I_load² · R_s = 10.0² × 0.010 Ω

⇒ 1.00 W (size ≥ 2.0 W part)

Nomenclature dynamique (BOM)

Réf.ComposantCalibrage calculéÉtat
Rs4-Terminal Manganin/Metal-Strip Shunt10 mΩ ±0.5%, ≤50 ppm/°C, ≥ 2 WOK
U1High-Side Current Sense AmplifierINA240 / INA180 (G = 20×, Vcm up to 80 V)OK
R/CInput Filtering (<10 Ω to preserve gain)2 × 4.7 Ω + 100 nF diff C0G (never >10 Ω on INA180!)OK

1. Présentation & principe de fonctionnement

Measuring DC motor, battery, or solenoid current with a precision milliohm shunt resistor and dedicated Current-Sense Amplifier (INA240 / INA180 / INA219) delivers wide dynamic range, DC-to-100 kHz bandwidth, and zero magnetic hysteresis at a fraction of Hall-effect sensor cost.

Two layout/topology decisions determine success: choosing High-Side sensing (keeps load grounded at 0.00 V and detects chassis shorts) vs Low-Side sensing (cheap, but introduces ground bounce), and routing true 4-terminal Kelvin sense traces straight from the shunt’s inner pads.

High-Side vs Low-Side: Putting Rs in the +24 V rail (High-Side) requires an amplifier rated for high common-mode voltage (e.g. INA240 up to 80 V even when powered from 3.3 V!), keeping load ground cleanly at 0 V and catching every load-to-chassis short. Low-side sensing lifts load ground by +I_load × Rs.

4-Terminal Kelvin Sensing: Copper PCB foil has a huge +3900 ppm/°C tempco! Even 3 mm of shared copper trace adds 2–4 mΩ in series with a 10 mΩ shunt — introducing +35% gain error that drifts wildly with temperature. Always tap differential sense lines from the inner edges of the shunt pads.

Amplificateur Shunt de Courant High-Side vs Low-Side (Kelvin) — SensorCatalog
Shunt High/Low-SidePNG 1200×630

2. Step-by-step: Designing a precision high-side Kelvin current-shunt stage

  1. 1Size Rs for 50–100 mV full-scale drop and ≥ 2× power margin

    Pick Rs = 0.05…0.10 V / I_max, then calculate P = I_max² × Rs and select a low-tempco (<50 ppm/°C) metal-strip shunt rated at least 2× higher than continuous dissipation.

  2. 2Choose a dedicated high-side amp rated above peak bus transients

    For a 24 V industrial rail (transients to 40–60 V), choose an 80 V common-mode amplifier like INA240 (with enhanced PWM rejection for motors) rather than a 26 V part.

  3. 3Route symmetrical 4-terminal Kelvin traces from inner shunt pads

    Never let high load current share any millimeter of the differential sense traces; route both sense wires tightly together to the amp inputs to reject magnetic flux pickup.

  4. 4Keep any input filter resistors strictly ≤ 10 Ω

    Integrated current-sense amps have low internal input impedance (~5–25 kΩ); adding 1 kΩ filter resistors ruins factory-trimmed gain accuracy! Keep series filter R ≤ 4.7–10 Ω.

3. Dépannage terrain & mesures au multimètre

SymptômeCause racineContrôle multimètreAction corrective
Measured current reads 20–40% higher than clamp meter and drifts as board warmsNon-Kelvin PCB sense traces picking up copper trace & solder resistanceInspect PCB layout around shunt pads; measure mV directly on shunt body vs amp pinsRe-spin with 4-terminal Kelvin shunt (e.g. CSS2H / WSLP) tapping inner pad edges only
Motor PWM spikes corrupt current readings on high-side ampFast dV/dt common-mode transitions exceed ordinary op-amp AC CMRRCompare output waveform synced to MOSFET gate PWM switching edgesUpgrade to PWM-rejection current-sense amp (INA240) + tight Kelvin pair

4. Questions fréquentes (FAQ)

Why is High-Side current sensing preferred over Low-Side in industrial and automotive systems?

High-side sensing keeps the load firmly at true chassis 0 V ground (no ground-bounce noise on CAN/RS-485/analog ports) AND detects dangerous load-to-chassis short circuits immediately.

Why can’t I use a regular LM358 op-amp for High-Side sensing on a 24 V bus?

An ordinary op-amp’s inputs cannot exceed its own power supply rail! Powering an LM358 from 5 V and touching 24 V destroys it instantly. Dedicated current-sense amps use precision high-voltage input stages rated 26–80 V independently of Vcc.

What full-scale shunt voltage drop is optimal?

50 mV to 100 mV is the engineering sweet spot: large enough to tower over amplifier input offset voltage (25–150 µV) and thermal EMF, yet small enough to keep I²R heat manageable.

Can a single shunt measure bidirectional battery charge AND discharge current?

Yes! Use a bidirectional current-sense amp (like INA240 or INA199) with its REF pin biased to Vcc/2 (e.g. 1.65 V on 3.3 V): positive current swings above 1.65 V and reverse current swings below 1.65 V.

Why does a tiny 10 Ω input filter resistor matter on an INA180?

Dedicated current-sense amps have internal precision input resistors (as low as 5 kΩ on high-gain models). Adding 1 kΩ in series creates a ~20% gain reduction! Keep external series filter resistors ≤ 10 Ω per datasheet.

When should I pick a Hall-effect current sensor instead of a shunt resistor?

Switch to Hall-effect or isolated sigma-delta (AMC1301) above ~50–100 A (where shunt heat becomes excessive) or whenever galvanic isolation from AC mains / high-voltage (>80 V) DC packs is mandatory.

5. Calculateurs associés, guides et autres circuits

↑ ↓ choisir · Entrée ouvrir · Échap fermer