SensorCatalog

Calcolatore sensore ultrasuoni

Velocità del suono compensata, tempo di eco andata-ritorno e diametro del fascio in aria.

In aria secca a 20 °C (c = 343,2 m/s), un eco a 3,0 m impiega 17,48 ms e un fascio di 10° raggiunge 0,52 m di diametro.

Target e aria

Risultato

17,33ms

Eco 17,33 ms · Fascio Ø 0,52 m · c = 346,1 m/s

Velocità suono c(T)
346,1 m/s25 °C
Diametro fascio
0,52 m525 mm
Frequenza max
38,5 Hzcon guardia 1,5×
Errore senza comp. 20 °C
-25,3 mmsenza sensore T

Schema

Ultrasonic40–200 kHz0,52 mBeam ØToF = 17,33 ms · c(T) = 346,1 m/s
Formule e norme
c(T) = 331.3 · √(1 + T / 273.15)   t_echo = 2·d / c(T)   D_beam = 2·d·tan(θ/2)

c(T) = 331,3 · √(1 + T / 273,15) m/s (~0,17 %/°C). Diametro del fascio a distanza d: 2·d·tan(θ/2).

Mantieni pareti serbatoio e agitatori fuori dal cono del fascio per evitare falsi echi.

Speed of sound and beam geometry

Ultrasonic level and distance sensors measure the round-trip Time of Flight (ToF) of a 40–200 kHz acoustic burst in air. Because speed of sound varies strongly with air temperature (~0,17 %/°C):

  • c(T) = 331,3 · √(1 + T / 273,15) m/s
  • t_echo = 2 · d / c(T)
  • D_beam = 2 · d · tan(θ / 2)

Worked example

At 3,0 m target distance, 20 °C air and a 10° full beam angle:

  • c(20 °C) = 343,2 m/s
  • Round-trip echo time = 17,48 ms (max ping rate ~38 Hz with 1,5× decay guard)
  • Beam spot diameter at target = 0,52 m (keep tank walls > 0,26 m from centerline)

Frequently asked questions

How much error does air temperature cause without compensation?

Air speed of sound changes by roughly 0,17 % per °C (about 0,6 m/s per °C). A 30 °C swing from 20 °C causes roughly 5 % range error (~150 mm at 3 m) unless temperature compensation is enabled.

Why does beam angle matter inside a tank or silo?

Any weld seam, ladder rung, inlet pipe or agitator blade inside the full beam diameter D_beam reflects an early false echo that locks the level reading above the true liquid surface.

Can ultrasonic sensors measure accurately in vacuum or steam?

No — acoustic waves require air/gas molecules and attenuate heavily in dense steam, foam or heavy dust. For vacuum, steam or high-pressure tanks, use 80 GHz FMCW radar or hydrostatic differential pressure.