SensorCatalog

Calcolatore encoder rotativo

Frequenza impulsi, conteggio 4× in quadratura e risoluzioni angolare e lineare.

Un encoder 2500 PPR a 1500 RPM genera 62,50 kHz per canale; in quadratura 4× produce 250,00 kHz e 0,0360° per conteggio.

Encoder e meccanica

Risultato

62,50kHz

Canale A: 62,50 kHz · Decodificato: 250,00 kHz (0,0360°/cnt)

Frequenza quadratura
250,00 kHz4× (10000 CPR)
Risoluzione angolare
0,0360 °2,16 arcmin/cnt
Velocità lineare
3,927 m/sD = 50,0 mm
Risoluzione lineare
15,71 µmper conteggio

Schema

2500 PPRCH ACH B (90°)62,50 kHz · 4× = 250,00 kHz
Formule e norme
f_pulse = PPR · RPM / 60   f_quad = f_pulse · Q   Δθ = 360° / (PPR · Q)

f_pulse = PPR · RPM / 60 Hz. La decodifica 4× rileva tutti i fronti A e B quadruplicando risoluzione e frequenza.

Assicurati che il contatore PLC superi 2× la frequenza decodificata e usa RS-422 sopra 50 kHz.

Rotary encoder frequency and resolution

An incremental rotary encoder outputs PPR (pulses per revolution) on channels A and B shifted by 90°. At shaft speed RPM:

  • f_pulse = PPR · RPM / 60 Hz
  • f_quad = f_pulse · Q (Q = 1, 2 or 4)
  • Δθ = 360° / (PPR · Q)

Worked example

For a 2500 PPR encoder running at 1500 RPM with 4× quadrature decoding on a 50 mm wheel:

  • Channel A frequency = 2500 × 1500 / 60 = 62,50 kHz
  • 4× decoded count rate = 250,00 kHz (10 000 counts/rev)
  • Angular resolution = 0,0360° (2,16 arcmin) per count
  • Linear surface speed = π × 0,05 m × 25 rev/s = 3,927 m/s (15,71 µm/count)

Frequently asked questions

What is the difference between PPR and CPR?

PPR (pulses per revolution) counts full cycles on a single channel (A). CPR (counts per revolution) after 4× quadrature decoding equals 4 × PPR because both rising and falling edges of A and B are counted.

When should I switch from open-collector/HTL to RS-422 differential?

Above ~50 kHz or cable runs longer than 10–15 m near VFD motor drives, use an RS-422 differential line driver with 120 Ω receiver termination — see the RS-422 encoder circuit.

How fast does my PLC high-speed counter need to be?

Size the PLC HSC or MCU timer bandwidth to at least 2× the 4× decoded quadrature frequency so edge jitter and duty-cycle asymmetry never drop counts.

↑ ↓ scegli · Invio apri · Esc chiudi