SensorCatalog

Calculadora de encoder rotativo

Frecuencia de pulsos, conteo 4× en cuadratura y resolución angular y lineal.

Un encoder de 2500 PPR a 1500 RPM genera 62,50 kHz por canal; en cuadratura 4× alcanza 250,00 kHz y 0,0360° por cuenta.

Encoder y mecánica

Resultado

62,50kHz

Canal A: 62,50 kHz · Decodificado: 250,00 kHz (0,0360°/cnt)

Frecuencia cuadratura
250,00 kHz4× (10000 CPR)
Resolución angular
0,0360 °2,16 arcmin/cnt
Velocidad lineal
3,927 m/sD = 50,0 mm
Resolución lineal
15,71 µmpor cuenta decodificada

Esquema

2500 PPRCH ACH B (90°)62,50 kHz · 4× = 250,00 kHz
Fórmulas y normas
f_pulse = PPR · RPM / 60   f_quad = f_pulse · Q   Δθ = 360° / (PPR · Q)

f_pulse = PPR · RPM / 60 Hz. La decodificación 4× cuenta todos los flancos de A y B, cuadruplicando resolución y frecuencia.

Verifique que el contador rápido del PLC supere 2× la frecuencia decodificada y use RS-422 sobre 50 kHz.

Rotary encoder frequency and resolution

An incremental rotary encoder outputs PPR (pulses per revolution) on channels A and B shifted by 90°. At shaft speed RPM:

  • f_pulse = PPR · RPM / 60 Hz
  • f_quad = f_pulse · Q (Q = 1, 2 or 4)
  • Δθ = 360° / (PPR · Q)

Worked example

For a 2500 PPR encoder running at 1500 RPM with 4× quadrature decoding on a 50 mm wheel:

  • Channel A frequency = 2500 × 1500 / 60 = 62,50 kHz
  • 4× decoded count rate = 250,00 kHz (10 000 counts/rev)
  • Angular resolution = 0,0360° (2,16 arcmin) per count
  • Linear surface speed = π × 0,05 m × 25 rev/s = 3,927 m/s (15,71 µm/count)

Frequently asked questions

What is the difference between PPR and CPR?

PPR (pulses per revolution) counts full cycles on a single channel (A). CPR (counts per revolution) after 4× quadrature decoding equals 4 × PPR because both rising and falling edges of A and B are counted.

When should I switch from open-collector/HTL to RS-422 differential?

Above ~50 kHz or cable runs longer than 10–15 m near VFD motor drives, use an RS-422 differential line driver with 120 Ω receiver termination — see the RS-422 encoder circuit.

How fast does my PLC high-speed counter need to be?

Size the PLC HSC or MCU timer bandwidth to at least 2× the 4× decoded quadrature frequency so edge jitter and duty-cycle asymmetry never drop counts.

↑ ↓ elegir · Intro abrir · Esc cerrar