SensorCatalog

Home › Sensor accuracy by temperature

Type B thermocouple accuracy at 1500 °C

What IEC 60584-1 allows a type B thermocouple at 1500 °C, class by class, and what the rest of the measurement adds.

Tolerance by class

ClassTolerance (°C)% of reading
1not defined at this temperature
2±3.75±0.25 %
3±7.50±0.50 %

At 1500 °C

EMF
10.099 mVcold junction at 0 °C
Sensitivity
11.56 µV/KNIST ITS-90
Cold-junction factor
0.004a 1 K error at 25 °C terminals reads as this many K

Example: the whole measurement

TermAssumptionError
Sensor toleranceClass 2±3.750 K
Cold junction±0.5 K, 25 °C±0.002 K
Transmitter input±0.5 K±0.500 K
Analog output±0.03 % × 1700 K±0.510 K
Ambient effect±0.1 % / 10 K × 20 K±3.400 K
Total probable errorRSS±5.11 K
Worst caseΣ±8.16 K

An example with typical datasheet figures, not a statement about any product. Enter your own values in the calculator.

Open this example in the error calculator

How the tolerance is defined

IEC 60584-1 gives each class as a fixed value or a fraction of |t|, whichever is larger, within a temperature range that depends on the type. The table is that rule evaluated at 1500 °C. The limits apply to new thermocouple wire as supplied; drift in service is not included.

Type B thermocouple: ranges, colour codes and tolerances

Need a sensor and transmitter that meet your total error?

Send your requirement to SensorSpan

↑ ↓ choose · Enter open · Esc close