Your customers already do these calculations: choosing an RTD class, sizing a current transformer's burden, decoding a Modbus register, biasing a thermistor. Let them do it for your part, in one click, with calculators that are checked against the standards they cite.

2 · Embed a calculator

Code for your page

  • Free, also for commercial sites. Keep the credit line under the frame; it links to the full calculator.
  • The embedded calculator shows no advertising and sets no cookies. We count views per embedding site (its host name only), nothing about the visitor.
  • It updates by itself when a calculator is corrected or improved. The results are the user's to check, as on this site (terms).
  • Please don't present the calculator as your own engineering, or a link to it as a review or an endorsement of your product.

Preview

3 · Your parts under the calculation

Each calculator turns its result into requirements: a PT100 element covering 0 to 150 °C, a current transformer of at least 3.2 VA, a loop-powered transmitter that works from 11.8 V. Under the calculation there is a reserved Matching products area. A part is shown there only when it meets every requirement; a part that lacks an attribute does not match. The area is labelled (Sponsored, Partner or Affiliate links) and kept apart from the calculation, and the calculation never changes for a sponsor.

Nothing is listed today. Parts appear only from data supplied by their manufacturer, or from a distributor feed whose terms allow it: we do not copy part data from datasheets ourselves. The data format:

FieldContent
idyour stable identifier for the part
categoryone of the categories below
brand, mpnbrand and manufacturer part number
nameshort English description
attrsthe attributes below that the part meets, in the units given
urlproduct page (may carry your own tracking parameters)
datasheetlink to the datasheet (optional)
regionsISO country codes where the part is sold (optional; all if left out)

Attributes

AttributeTypeMeaning
elementtextRTD element: 'PT100', 'PT500', 'PT1000', 'Ni100', 'Ni1000'
wiresnumberRTD connection: 2, 3 or 4 wires
tc_typetextthermocouple type letter, e.g. 'K'
temp_range_c[lo, hi]operating temperature range, °C
inputtexttransmitter or indicator input: 'RTD', 'TC', 'mV/V'
outputtext'4-20mA', '4-20mA-HART', 'mV/V' …
min_supply_vnumberminimum terminal voltage of a loop-powered device, V
pressure_url_panumberupper range limit, Pa
ref_accuracy_pctnumberreference accuracy, % of span
capacity_kgnumberrated capacity per load cell, kg
channelsnumberload cell inputs of a junction box
r25_ohmnumberNTC resistance at 25 °C, Ω
beta_knumberNTC beta value, K
burden_vanumberrated burden of a current transformer, VA
rh_range_pct[lo, hi]relative humidity range, %
accel_range_gnumberacceleration range, g
freq_range_hz[lo, hi]frequency range, Hz
iptextingress protection code, e.g. 'IP67'
threadtextprocess or cable thread, e.g. 'G 1/2', '1/2 NPT'
ex_epltextequipment protection level, e.g. 'Gb'
ex_grouptextgas or dust group, e.g. 'IIC'
max_surface_temp_cnumbermaximum surface temperature, °C (from the T class)
nec_class_divisiontexte.g. 'Class I Div 1'
nec_groupstextNEC groups, e.g. 'B'

Categories

accelerometercable-glandcurrent-sensorcurrent-transformerdew-point-transmitterdp-flow-transmitterdp-transmitterencoderex-pressure-transmitterex-sensorex-temperature-sensorex-transmitterflow-meterhumidity-sensorhumidity-transmitterjunction-boxlevel-transmitterload-cellloop-power-supplyloop-powered-isolatorntc-probentc-thermistorpressure-transmitterrtd-cablertd-elementrtd-probesensorshuntsignal-isolatorstrain-gaugetemperature-sensortemperature-transmitterthermocouple-cablethermocouple-probethread-adaptertransmittertwo-wire-transmittervibration-sensorvibration-transmitterweighing-indicatorwireless-sensor

Why engineers can rely on the numbers

  • Each calculator states its method and the standard it follows (IEC 60751, IEC 60584-1, NAMUR NE 43, IEC 60079 and others) on its own page.
  • Every build compares the calculators with published reference tables and worked examples; a deviation beyond tolerance stops the build. The comparison is public: how the results are checked.
  • No account, no paywall, in seven languages, and it works offline once opened.

Contact

For a calculator your product family needs, product data for the Matching products area, a co-branded embed, or a question about the link format: [email protected]. Please say which calculators and which parts it is about.

↑ ↓ choose · Enter open · Esc close