1. 회로 개요 및 동작 원리
Unlike IEPE accelerometers with built-in electronics, bare piezoelectric crystals (force washers, ultrasonic transducers, high-temperature >250 °C vibration sensors) output pure electric charge Q (pC). A Charge Amplifier integrates Q across feedback capacitor C_f (V_out = −Q / C_f), making sensitivity 100% immune to coaxial cable length!
Cable-Capacitance Immunity: Because the op-amp inverting (−) terminal is held at 0 V virtual ground, the coaxial cable capacitance C_cab has 0 V across it and draws zero charge — all charge Q transfers directly into C_f.
Mandatory Gigaohm Reset Resistor R_f: Without R_f across C_f, picoamp op-amp bias current integrates continuously until output hits the supply rail. R_f stabilizes DC at 0 V and sets the low-frequency −3 dB cutoff f_LP = 1 / (2π · R_f · C_f).

2. Step-by-step: Designing a low-noise piezoelectric charge amplifier
1Pick C_f = Q_max / V_out(max) using C0G or polystyrene
1000 pF gives a clean 1.00 mV/pC transfer ratio with near-zero dielectric absorption.
2Select R_f for your required low-frequency cutoff f_LP
100 MΩ × 1000 pF yields f_LP = 1.59 Hz; use 1 GΩ for quasi-static 0.16 Hz force pulses.
3Choose a low-Ib, low-noise JFET op-amp (OPA657 / AD8610)
Remember that cable capacitance still amplifies op-amp voltage noise by Noise Gain = 1 + C_cab / C_f.
4Use low-triboelectric-noise coaxial cable for high-vibration runs
Standard RG58 generates fake pC charge spikes when flexed; graphite-lubricated low-noise piezo cables eliminate cable-whip artifacts.
3. 현장 트러블슈팅 및 멀티미터 점검
| 증상 | 근본 원인 | 멀티미터 점검 | 조치 방법 |
|---|---|---|---|
| Output slowly drifts to −12 V rail after power-up with no force applied | Open/missing R_f or contaminated PCB leakage into summing node | Verify R_f continuity and wash summing node with IPA | Install 100 MΩ–1 GΩ R_f and add driven Guard Ring around (−) pin |
4. 자주 묻는 엔지니어링 질문 (FAQ)
Can a charge amplifier measure true static (DC) weight forever?
No — because R_f (and finite insulation resistance) gradually bleeds charge off C_f with time constant τ = R_f·C_f. Use a Wheatstone strain-gauge load cell for permanent static weighing.
5. 관련 계산기, 비교 가이드 및 다른 센서 회로
- 초음파 센서 거리·빔 계산기
- 진동 변환기
- 앤티앨리어싱 RC 필터 계산기
- 포토다이오드 트랜스임피던스 증폭기 (TIA) 회로
- 하이사이드 vs 로우사이드 켈빈 전류 션트 증폭 회로
- 압전 / IEPE (ICP) 정전류 바이어스 & AC 커플링 회로
- 히스테리시스 비교기 (슈미트 트리거) 임계값 검출 회로
- AC 변류기(CT) 버든 저항, Vref/2 바이어스 & 개방 고압 보호
- SAR ADC RC 차지 버킷(킥백) 필터 & 세틀링 시간 검증
- 3전극 전기화학 가스 센서(CO / O2 / H2S) 포텐시오스탯
- PNP (소싱) 3선식 센서 출력 회로 시뮬레이터
- NPN (싱킹 / 오픈컬렉터) 3선식 센서 출력 회로
- NAMUR 2선식 본질안전 방폭 센서 회로 (IEC 60947-5-6)
- 2선식 4–20 mA 전류 루프 & ADC 보호 수신 회로