1. 회로 개요 및 동작 원리
Measuring DC motor, battery, or solenoid current with a precision milliohm shunt resistor and dedicated Current-Sense Amplifier (INA240 / INA180 / INA219) delivers wide dynamic range, DC-to-100 kHz bandwidth, and zero magnetic hysteresis at a fraction of Hall-effect sensor cost.
Two layout/topology decisions determine success: choosing High-Side sensing (keeps load grounded at 0.00 V and detects chassis shorts) vs Low-Side sensing (cheap, but introduces ground bounce), and routing true 4-terminal Kelvin sense traces straight from the shunt’s inner pads.
High-Side vs Low-Side: Putting Rs in the +24 V rail (High-Side) requires an amplifier rated for high common-mode voltage (e.g. INA240 up to 80 V even when powered from 3.3 V!), keeping load ground cleanly at 0 V and catching every load-to-chassis short. Low-side sensing lifts load ground by +I_load × Rs.
4-Terminal Kelvin Sensing: Copper PCB foil has a huge +3900 ppm/°C tempco! Even 3 mm of shared copper trace adds 2–4 mΩ in series with a 10 mΩ shunt — introducing +35% gain error that drifts wildly with temperature. Always tap differential sense lines from the inner edges of the shunt pads.

2. Step-by-step: Designing a precision high-side Kelvin current-shunt stage
1Size Rs for 50–100 mV full-scale drop and ≥ 2× power margin
Pick Rs = 0.05…0.10 V / I_max, then calculate P = I_max² × Rs and select a low-tempco (<50 ppm/°C) metal-strip shunt rated at least 2× higher than continuous dissipation.
2Choose a dedicated high-side amp rated above peak bus transients
For a 24 V industrial rail (transients to 40–60 V), choose an 80 V common-mode amplifier like INA240 (with enhanced PWM rejection for motors) rather than a 26 V part.
3Route symmetrical 4-terminal Kelvin traces from inner shunt pads
Never let high load current share any millimeter of the differential sense traces; route both sense wires tightly together to the amp inputs to reject magnetic flux pickup.
4Keep any input filter resistors strictly ≤ 10 Ω
Integrated current-sense amps have low internal input impedance (~5–25 kΩ); adding 1 kΩ filter resistors ruins factory-trimmed gain accuracy! Keep series filter R ≤ 4.7–10 Ω.
3. 현장 트러블슈팅 및 멀티미터 점검
| 증상 | 근본 원인 | 멀티미터 점검 | 조치 방법 |
|---|---|---|---|
| Measured current reads 20–40% higher than clamp meter and drifts as board warms | Non-Kelvin PCB sense traces picking up copper trace & solder resistance | Inspect PCB layout around shunt pads; measure mV directly on shunt body vs amp pins | Re-spin with 4-terminal Kelvin shunt (e.g. CSS2H / WSLP) tapping inner pad edges only |
| Motor PWM spikes corrupt current readings on high-side amp | Fast dV/dt common-mode transitions exceed ordinary op-amp AC CMRR | Compare output waveform synced to MOSFET gate PWM switching edges | Upgrade to PWM-rejection current-sense amp (INA240) + tight Kelvin pair |
4. 자주 묻는 엔지니어링 질문 (FAQ)
Why is High-Side current sensing preferred over Low-Side in industrial and automotive systems?
High-side sensing keeps the load firmly at true chassis 0 V ground (no ground-bounce noise on CAN/RS-485/analog ports) AND detects dangerous load-to-chassis short circuits immediately.
Why can’t I use a regular LM358 op-amp for High-Side sensing on a 24 V bus?
An ordinary op-amp’s inputs cannot exceed its own power supply rail! Powering an LM358 from 5 V and touching 24 V destroys it instantly. Dedicated current-sense amps use precision high-voltage input stages rated 26–80 V independently of Vcc.
What full-scale shunt voltage drop is optimal?
50 mV to 100 mV is the engineering sweet spot: large enough to tower over amplifier input offset voltage (25–150 µV) and thermal EMF, yet small enough to keep I²R heat manageable.
Can a single shunt measure bidirectional battery charge AND discharge current?
Yes! Use a bidirectional current-sense amp (like INA240 or INA199) with its REF pin biased to Vcc/2 (e.g. 1.65 V on 3.3 V): positive current swings above 1.65 V and reverse current swings below 1.65 V.
Why does a tiny 10 Ω input filter resistor matter on an INA180?
Dedicated current-sense amps have internal precision input resistors (as low as 5 kΩ on high-gain models). Adding 1 kΩ in series creates a ~20% gain reduction! Keep external series filter resistors ≤ 10 Ω per datasheet.
When should I pick a Hall-effect current sensor instead of a shunt resistor?
Switch to Hall-effect or isolated sigma-delta (AMC1301) above ~50–100 A (where shunt heat becomes excessive) or whenever galvanic isolation from AC mains / high-voltage (>80 V) DC packs is mandatory.
5. 관련 계산기, 비교 가이드 및 다른 센서 회로
- 전류 션트 저항 계산기
- 변류기(CT) 부담 계산기
- ADC 분해능 계산기
- 포토다이오드 트랜스임피던스 증폭기 (TIA) 회로
- 압전 / IEPE (ICP) 정전류 바이어스 & AC 커플링 회로
- 히스테리시스 비교기 (슈미트 트리거) 임계값 검출 회로
- AC 변류기(CT) 버든 저항, Vref/2 바이어스 & 개방 고압 보호
- SAR ADC RC 차지 버킷(킥백) 필터 & 세틀링 시간 검증
- 3전극 전기화학 가스 센서(CO / O2 / H2S) 포텐시오스탯
- 압전 차지 앰프 (동축 케이블 정전용량 무관 전하 증폭)
- PNP (소싱) 3선식 센서 출력 회로 시뮬레이터
- NPN (싱킹 / 오픈컬렉터) 3선식 센서 출력 회로
- NAMUR 2선식 본질안전 방폭 센서 회로 (IEC 60947-5-6)
- 2선식 4–20 mA 전류 루프 & ADC 보호 수신 회로